| | 280 mm 11.024 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | 630 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 280 mm 11.024 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | 800 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 920 mm 36.221 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 35 mA or less Receiver: 115 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | 2,190 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 920 mm 36.221 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC ±10 % Ripple P-P 10 % or les | Emitter: 35 mA or less Receiver: 115 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 200 mm 7.874 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | 630 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 200 mm 7.874 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC ±10 % Ripple P-P 10 % or les | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 120 mm 4.724 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | 500 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 200 mm 7.874 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | Emitter: 30 mA or less Receiver: 60 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm2, or more, cable. (However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.) | 500 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | 760 mm 29.921 in | 5 m 16.404 ft | 40 mm 1.575 in | ø60 mm ø2.362 in or more opaque object | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 35 mA or less Receiver: 115 mA or less | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1.6 V or less (at 100 mA sink current) | ON when all beam channels are received / OFF when one or more beam channels are interrupted | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) • Residual voltage: 1.6 V or less (at 50 mA sink current) | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails | Incorporated | 12 ms or less | Incorporated (Two units of sensors can be mounted close together.) | Incorporated with the three color indicators on the receiver • Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted) • Stable incident beam indicator: Green LED (lights up when all beam channels are received stably) • Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably) * When the output transistor fails, the three color indicators blink simultaneously. | IP65 (IEC) | –10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: –10 to +60 ℃ +14 to +140 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 ℓx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Infrared LED (synchronized scanning system) | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic | | 0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end * Use together with the optional mating cable | 1,840 g approx. | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |