Specification

Specifications table for model BSF4-AH80
ItemPerformance characteristics
CE Marking Directive ComplianceATEX Directive, Machinery Directive, EMC Directive, RoHS Directive
Applicable Flameproof StandardsEurope: EN 60079-0, EN60079-1, EN 60079-28,
USA: FM Class 3600, ANSI/ISA.12.00.01, ANSI/ISA.12.22.01,
Canada: CAN/CSA E60079-0, CAN/CSA E60079-1,
Russia: TP TC 012/2011, ГOCT P MЭК 60079-0, ГOCT MЭК 60079-1, ГOCT 31610.28/IEC 60079-28,
China: GB 3836.1/2,
Japan: Technical standard conforming to IEC Standard 79
Flameproof CapabilityUSA: Class I Zone 1 AEx d IIB T6, Europe / Canada / Russia / China / Japan: Ex d IIB T6
Setup LocationHazardous locations such as Zone 1 or Zone 2 where "II BT6" gases or vapors may be present
(Note) : Install the product in a location where it is less likely to suffer mechanical damage.
Applicable StandardsISO 13849-1 (Category 4, PLe), EN ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 4 (SIL 3), EN 50178, EN 55011, EN 61000-6-2, EN 61496-1 (Type 4), IEC 61496-1/2 (Type 4), UL 61496-1/2 (Type 4), CAN/CSA-C22.2 No. 14
Protective Height 1,595 mm 62.795 in
Beam Pitch20 mm 0.787 in
Operating Range0.3 to 6 m 0.984 to 19.686 ft
Min. Sensing Objectø30 mm ø1.181 in opaque object
Effective Aperture Angle± 2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
Power Voltage 24 V DC ± 10 % Ripple P-P 10 % or less
Current ConsumptionEmitter: 130 mA or less
Receiver: 125 mA or less
Control Outputs (OSSD 1, OSSD 2)Semiconductor output (PNP output equivalent) 2 outputs
- Maximum source current: 200 mA
- Applied voltage: Same as supply voltage (between control output and +V)
- Residual voltage: 3.0 V or less (at 200 mA source current)
Control Outputs (OSSD 1, OSSD 2): Operation ModeON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) / Incorporated
Control Outputs (OSSD1, OSSD2): Protection CircuitIncorporated
Response TimeOFF response: 11 ms or less
ON response: 70 ms or less
Auxiliary Output (Non-Safety Output)PNP open-collector transistor
- Maximum source current: 60 mA
- Applied voltage: Same as supply voltage (between auxiliary output and +V)
- Residual voltage: 2.5 V or less (at 60 mA source current)
Auxiliary Output (Non-Safety Output): Operation ModeOFF when control outputs are ON, ON when control outputs are OFF
Auxiliary Output (Non-Safety Output): Protection CircuitIncorporated
Indicators: Emitter Top beam-axis alignment indicator: 2-color (Red / Blue) LED (lights up in blue when control outputs are ON, lights up in red when the topmost beam channel receives light, lights off when the topmost beam channel is interrupted)
Bottom beam-axis alignment indicator: 2-color (Red / Blue) LED (lights up in blue when control outputs are ON, lights up in red when the bottommost beam channel receives light, lights off when the bottom most beam channel is interrupted)
Emission control indicator: Orange LED (lights up in orange during emission halt, lights off during normal operation)
Operation indicator: 2-color (Red / Green) LED (lights up in red when control outputs are OFF, lights up in green when control outputs are ON)
Fault indicator: Yellow LED (lights up or blinks if a fault occurs in the safety light curtain)
Indicators: ReceiverTop beam-axis alignment indicator: 2-color (Red / Blue) LED (lights up in blue when control outputs are ON, lights up in red when the topmost beam channel receives light, lights off when the topmost beam channel is interrupted)
Bottom beam-axis alignment indicator: 2-color (Red / Blue) LED (lights up in blue when control outputs are ON, lights up in red when the bottommost beam channel receives light, lights off when the bottom most beam channel is interrupted)
Stable light indicator : 2-color (Green / Orange) LED (lights up in green when stable light state, lights up in orange when unstable light state, lights off when beam channels are interrupted)
OSSD indicator: 2-color (Red / Green) LED (lights up in red when control outputs are OFF, lights up in green when control outputs are ON)
Fault indicator: Yellow LED (lights up or blinks if a fault occurs in the safety light curtain)
Emission Halt FunctionIncorporated
Test Input (Emission Halt Input) Emission: Vs-2.5 V to Vs (sink current: 5 mA or less) (Note), Emission halt: Open, or 0 to +1.5 V
(Note) : Vs is the same value as the voltage of the used power supply to be used.
Environmental Resistance: Degree of ProtectionIP65 (IEC)
Ambient Temperature-10 to +40 ℃ +14 to +104 ℉ (No dew condensation or icing allowed), Storage: -20 to +55 ℃ -4 to +131 ℉
Ambient Humidity45 to 85 % RH, Storage: 45 to 85 % RH
Ambient IlluminanceIncandescent light: 5,000 lx or less at the light-receiving face
Environmental Resistance: Dielectric Strength Voltage1,000 V AC for one min. between all supply terminals connected together and safety light curtain grounding terminal
(Note) It shows the specifications of the built-in safety light curtain.
Insulation Resistance20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and safety light curtain grounding terminal
(Note) It shows the specifications of the built-in safety light curtain.
Vibration Resistance10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y and Z directions for 20 times each
Shock Resistance100 m/s2 acceleration (10 G approx.) with pulse width 16 ms in X, Y and Z directions 1,000 times each
Altitude (Atmospheric Pressure)2,000 m 6561 ft or less (800 to 1,100 hPa)
Emitting ElementInfrared LED (Peak emission wavelength: 850 nm 0.033 mil)
MaterialFlameproof enclosure: Aluminum
Lid: Aluminum die-cast
Clear window: Glass
Window frame: Steel plate (Black chromate)
Window packing: Chloroprene
Safety light curtain mounting bracket: Steel plate (Black chromate)
Cable: Oil-resistant PVC
Cable Gland: Brass (Nickel plated)
Cable6-core (0.3 mm2 × 4-core, 0.2 mm2 × 2-core) shielded cable, 20 m 65.617 ft long
Weight (Total Of Emitter And Receiver)Net weight: 44 kg approx.
AccessoriesRear sensor mounting bracket: 1 set for emitter and receiver
Test rod: 1 pc.
Gland adapter (Internal thread G 1/2): 2 pcs.

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.