Specification

Specifications table for model SF-C12
ItemPerformance characteristics
Connectable Safety Light CurtainsSF4B / SF4B-G series
Applicable Standards: International StandardIEC 61496-1 (Type 4)
CE Marking Directive ComplianceMachinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive
Applicable Standards: JapanJIS B 9704-1 (Type 4), JIS B 9705-1(Category 4),
Applicable Standards: Europe (EU)EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11 and SF-C13 comply with UL 1998 (Class 2).)
Applicable Standards: North AmericaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11 and SF-C13 comply with UL 1998 (Class 2).)
Power Voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current Consumption100 mA or less (without light curtain)
Fuse RatingBuilt-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Safety OutputNO contact × 2 (13-14, 23-24)
Safety Output: Application CategoryAC-15, DC-13 (IEC 60947-5-1)
Safety Output: Rated Operation Voltage (Ue)/Rated Operation Current (le)1 A / 24 V DC, resistive load (For inductive load, during contact protection) Min. applicable load: 15 mA (at 24 V DC)
Safety Output: Contact Material/Contacts AgNiO + 0.2 micro m 0.008 mil Au plating, self cleaning, positively driven
Safety Output: Contact Resistance50 mOhm or less (initial value)
Safety Output: Contact Protection Fuse Rated3 A (slow blow)
Safety Output: Mechanical Lifetime10,000,000 times or more (open/close frequency of 180 times/min)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Safety Output: Electrical Lifetime100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Pick-Up Delay (Auto Reset/Manual Reset) 30 ms or less / 30 ms or less
Response Time14 ms or less
Auxiliary OutputsSafety relay contact (NC contact) × 1 (31-32) (Related to enabling path)
Auxiliary Output: Rated Operation Voltage / Current30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC)
Auxiliary Output: Contact Protection Fuse Rated3 A (slow blow)
Semiconductor Auxiliary Output (Aux)-
Semiconductor Auxiliary Output (Aux): Output Operation-
Overvoltage Category III
Indicators: Power Supply (Ui)Green LED (lights up when the power is ON)
Indicators: Safety Output [OUT]Green LED (lights up when safety output is closed)
(Note:The operation indicator is marked as "Enabling" on the unit for SF-C12.)
Indicators: Interlock -
Indicators: Fault (Fault) Orange LED (lights up when two safety light curtain input polarity selection switch settings are different)
External Relay Monitor FunctionIncorporated
(Note:Terminals for utilizing the functions of the SF4B / SF4B-G series are available.)
Trailing Edge FunctionIncorporated
Pollution Degree 2
Polarity Selection FunctionIncorporated (Sliding switch allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain
(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.)
Environmental Resistance: Degree of ProtectionIP65
Ambient Temperature-10 to +55 ℃ +14 to +131
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Vibration ResistanceResistance 10 to 55 Hz frequency, 0.75 mm 0.030 in amplitude
in X, Y, and Z directions for two hours each
Enclosure MaterialDie-cast aluminium
Connection TerminalEuropean terminal
Weight (Typ.)Net weight: 1 kg approx.
DummyCE Marking (Machinery Directive, EMC Directive, RoHS Directive)
Applicable StandardsEN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), ANSI/UL 61496-1 (Type 4)
Excess Voltage CategoryIII