Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C

Ultra Slim Safety Light Curtain With LED Indicators, Type 4

The SF4C Series Ultra-Slim Safety Light Curtain has been designed to offer a safeguarding solution for machines to make them safe for the operators without sacrificing productivity. The ultra-slim size and shape of the SF4C Series (13mm) allow it to fit efficiently into small machinery while maximizing the usable working space for the equipment operator.

SF4C Series is an Ultra-Slim Safety Light Curtain with large LED bars on each side of the Light Curtain. The LED bars provide a large, visible indicator that can be customized for various applications with the help of independent external inputs. The indicator can be used as an operation indicator, as an error indicator or as a muting lamp.

Characteristics

  • Large Built-In Multi-Purpose LED Indicators
  • Auto-Interference Prevention = ELCA Function
  • 4 Blocks Of Beam-Axis Adjustment Indicators
  • Digital Error Display
  • Output Polarity Setting
  • IP67 Protection
  • Fast Response Time Of 7ms For All Models
  • Various Blanking Functions
  • Manual Reset / Auto Reset
  • External Device Monitor
  • Override Function
  • New! 2 N.C. Safety Inputs
  • New! Various Muting Functions (e.g. Exit Muting Control)

Part Number List

Results 31
Models table for series Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
Part No.DatasheetNo. of Beam ChannelsProtective Height Current Consumption: Large Multipurpose Indicator Lights OffCurrent Consumption: Large Multipurpose Indicator Lights UpPFH<sub>D</sub>MTTF<sub>D</sub>Net Weight (Total of Emitter and Receiver) Applicable Standards: International StandardApplicable Standards: JapanApplicable Standards: Europe (EU)Applicable Standards: North AmericaOperating RangeBeam PitchMin. Sensing ObjectEffective Aperture AnglePower Voltage Control Outputs (OSSD 1, OSSD 2)Control Outputs (OSSD 1, OSSD 2): Operation ModeControl Outputs (OSSD1, OSSD2): Protection CircuitAuxiliary Output (Non-Safety Output)Response TimeAuxiliary Output (Non-Safety Output): Operation ModeAuxiliary Output (Non-Safety Output): Protection CircuitELCA Function Test/Reset Input FunctionInterlock FunctionExternal Device Monitoring FunctionSafety Input FunctionMuting Function Override FunctionOptional FunctionsPollution Degree Operating AltitudeEnvironmental Resistance: Degree of ProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceEnvironmental Resistance: Dielectric Strength VoltageInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialCableCable ExtensionAccessoriesDirective Compliance
39
400 mm 15.748 in
Emitter: 80 mA or less
Receiver: 90 mA or less
Emitter: 115 mA or less
Receiver: 120 mA or less
3.62 × 10-9
100 years or more
400 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
31
320 mm 12.598 in
Emitter: 75 mA or less
Receiver: 85 mA or less
Emitter: 110 mA or less
Receiver: 115 mA or less
3.18 × 10-9
100 years or more
730 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
47
480 mm 18.898 in
Emitter: 80 mA or less
Receiver: 90 mA or less
Emitter: 115 mA or less
Receiver: 120 mA or less
4.06 × 10-9
100 years or more
860 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
15
160 mm 6.299 in
Emitter: 70 mA or less
Receiver: 80 mA or less
Emitter: 105 mA or less
Receiver: 110 mA or less
2.29 × 10-9
100 years or more
210 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
12
240 mm 9.449 in
Emitter: 70 mA or less
Receiver: 90 mA or less
Emitter: 120 mA or less
Receiver: 140 mA or less
1.90 × 10-9
100 years or more
700 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification, S-mark certification
39
400 mm 15.748 in
Emitter: 80 mA or less
Receiver: 90 mA or less
Emitter: 115 mA or less
Receiver: 120 mA or less
3.62 × 10-9
100 years or more
800 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
55
560 mm 22.047 in
Emitter: 85 mA or less
Receiver: 95 mA or less
Emitter: 120 mA or less
Receiver: 125 mA or less
4.50 × 10-9
100 years or more
930 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
10 mm 0.394 in
ø14 mm ø0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 9 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR14 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
24
480 mm 18.898 in
Emitter: 75 mA or less
Receiver: 95 mA or less
Emitter: 120 mA or less
Receiver: 145 mA or less
2.54 × 10-9
100 years or more
880 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m 16.404 ft long
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification, S-mark certification
24
480 mm 18.898 in
Emitter: 75 mA or less
Receiver: 95 mA or less
Emitter: 120 mA or less
Receiver: 145 mA or less
2.54 × 10-9
100 years or more
490 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3)
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
24 V DC +10-15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 200 mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less

[When selecting NPN output]
- Max. sink current: 200 mA
- Applied voltage: same as supply voltage (between the control output and 0 V)
- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable)
- Leakage current: 200 micro A or less (including power supply OFF condition)
- Max. load capacity: 1 micro F (No load to Max. output current)
- Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
PNP open-collector transistor / NPN open-collector transistor (switching method)
[When selecting PNP output]
- Max. source current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and +V)
- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

[When selecting NPN output]
- Max. sink current: 100 mA
- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less
ON response: 90 ms or less
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Incorporated
Incorporated (reducing mutual interference automatically)
Incorporated
Incorporated [Manual reset / Automatic reset (Note)]
(Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated (safety contact)
Incorporated
Incorporated
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting
(Note) In case of using optional function, the handy-controller SFC-HC is required.
3
2,000 m 6,561 68 ft or less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +60 ℃ -13 to +140 ℉
30 to 85 % RH, Storage: 30 to 85 % RH
Incandescent light: 5,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 855 nm 0.034 mil)
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
0.15mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable, 0.5 m 1.640 ft long with connector
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable.
(Note) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver).
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification, S-mark certification