Robust Safety Light Curtain [Category4 PLe SIL3] SF4B-□G Ver.2

SF4B-G Safety Light Curtains, Type 4, PLe - Robust Design

There are more the 40 different models in the SF4B-G Series Safety Light Curtains from Panasonic and their modular design makes them easy to expand. These compact Type 4 Safety Light Curtains comply with EN 61496-1 /-2 and EN ISO 13849 performance level (PLe). The SF4B Series are available in three (3) different beam pitches (10 mm, 20 mm and 40 mm) and in numerous sensing heights.

The SF$B-G Series offers flexibility and wide range of accessories such as mounting brackets and extension cables. Cables for Series connection are also available to eliminate dead zones.  The SF4B-G can now be equipped with corner mirrors to reduce setup work and wiring.

Part Number List

Results 56
Models table for series Robust Safety Light Curtain [Category4 PLe SIL3] SF4B-□G Ver.2
Part No.DatasheetCE Marking Directive ComplianceNo. of Beam ChannelsProtective Height Protective Height: China Press Compliant (GB/T 4584)Current ConsumptionPFH<sub>D</sub>MTTF<sub>D</sub>Weight (Total Of Emitter And Receiver)Applicable Standards: International StandardApplicable Standards: JapanApplicable Standards: Europe (EU)Applicable Standards: North AmericaApplicable Standards: China (GB)Operating RangeMin. Sensing ObjectEffective Aperture AnglePower Voltage Control Outputs (OSSD 1, OSSD 2)Control Outputs (OSSD 1, OSSD 2): Operation ModeControl Outputs (OSSD1, OSSD2): Protection CircuitResponse TimeAuxiliary Output (Non-Safety Output): Operation ModeAuxiliary Output (Non-Safety Output)Auxiliary Output (Non-Safety Output): Protection CircuitAuxiliary Output (Non-Safety Output): Response TimeInterference Prevention FunctionEmission Halt FunctionInterlock FunctionExternal Device Monitoring FunctionOverride FunctionMuting Function Optional FunctionsEnvironmental Resistance: Degree of ProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceEnvironmental Resistance: Dielectric Strength VoltageInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialConnecting MethodCable LengthAccessoriesApplicable Standards: China
Machinery Directive, EMC Directive, RoHS Directive
111
1,124 mm 44.252 in
1,100mm 43.306 in
Emitter: 135 mA or less
Receiver: 230 mA or less
6.8x10-9
100 years or more
5,000 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 7 m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 14 mm dia. 0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
MS-SF4BG-2 (Intermediate supporting bracket): 1 set
SF4B-TR14 (Test rod): 1 No
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
6
244 mm 9.606 in
200mm
Emitter: 65 mA or less
Receiver: 85 mA or less
1.5x10-9
100 years or more
980 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
28
1,124 mm 44.252 in
1,080mm
Emitter: 80 mA or less
Receiver: 120 mA or less
2.6x10-9
100 years or more
5,000 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
MS-SF4BG-2 (Intermediate supporting bracket): 1 set
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
44
1,764 mm 69.449 in
1,720mm
Emitter: 95 mA or less
Receiver: 140 mA or less
3.4x10-9
100 years or more
7,800 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 7 m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
MS-SF4BG-2 (Intermediate supporting bracket): 2 set
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
32
1,284 mm 50.551 in
1,240mm
Emitter: 80 mA or less
Receiver: 120 mA or less
2.8x10-9
100 years or more
5,600 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
MS-SF4BG-2 (Intermediate supporting bracket): 1 set
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
10
404 mm 15.906 in
360mm
Emitter: 65 mA or less
Receiver: 85 mA or less
1.7x10-9
100 years or more
1,700 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
18
724 mm 28.504 in
680mm
Emitter: 70 mA or less
Receiver: 95 mA or less
2.1x10-9
100 years or more
3,200 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
16
644 mm 25.354 in
600mm
Emitter: 70 mA or less
Receiver: 95 mA or less
2.0x10-9
100 years or more
2,800 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 45 mm dia. 1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
79
804 mm 31.654 in
780mm 30.708 in
Emitter: 115 mA or less
Receiver: 190 mA or less
5.2x10-9
100 years or more
3,400 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 7 m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 14 mm dia. 0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
MS-SF4BG-2 (Intermediate supporting bracket): 1 set
SF4B-TR14 (Test rod): 1 No
GB/T 4584 (excluding SF4B-□-03)
Machinery Directive, EMC Directive, RoHS Directive
47
484 mm 19.055 in
460mm 18.110 in
Emitter: 100 mA or less
Receiver: 160 mA or less
3.6x10-9
100 years or more
2,000 g approx.
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
GB/T 4584 (excluding SF4B-□-03)
0.3 to 7 m 0.984 to 22.966 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
dia. 14 mm dia. 0.551 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
plus or minus 2.5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / UL 61496-2)]
24 V DC plus or minus 10 % Ripple P-P 10 % or less
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA
- When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Incorporated
OFF response: 14 ms or less
ON response: 80 to 90 ms
OFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller).
PNP open-collector transistor/NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA
- When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Incorporated
OFF replay: 34 ms or less, ON replay: 110 ms or less
Incorporated
(Note) Please use 12-core cable.
Incorporated
Incorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
Incorporated
Incorporated
(Note) Please use 12-core cable.
Incorporated
(Note) Please use 12-core cable.
Fixed blanking, floating blanking, auxiliary output switching, interlock setting changing, external relay monitor setting changing, muting setting changing, protecting, light emitting amount control
(Note)In case of using optional function, the handy-controller (SFB-HC) (optional) is required. However, a handy-controller cannot be used with the SF4B-□-01, SF4B-□-03 and the SF-C14EX-01.
IP67 / IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃ -13 to +158 ℉
30 to 85 % RH, Storage: 30 to 95 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 870 nm 0.034 mil)
Enclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connector
Total length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three safety light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
SF4B-TR14 (Test rod): 1 No
GB/T 4584 (excluding SF4B-□-03)