Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C

Introducing Type 2 Ultra-Slim Light Curtains!

The Ultra-Slim SF2C Light Curtains have a thickness of only 13.2mm, come in an ultra-light polycarbonate enclosure and features easy installation and reduced wiring. They are available as a hand protection type with a beam pitch of 20mm, allowing users to detect objects as small as 25mm in diameter. SF2C Light Curtains are delivered with a 3-meter cable and mounting brackets (MS-SFC-1).

Characteristics

  • Easy Beam Axis Alignment Due To Large Aperture Angle
  • Less Mounting Effort Due To Reduced Wiring
  • Slim Size For Compact Applications
  • Very Lightweight Due To Polycarbonate Enclosure
  • Optimum Small Width Of Only 13.2mm
  • Interference Prevention Output
  • IP67 Protection

Part Number List

Results 14
Models table for series Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C
Part No.DatasheetCE Marking Directive ComplianceNo. of Beam ChannelsProtective Height Current Consumption: Large Multipurpose Indicator Lights OffPFH<sub>D</sub>Current Consumption: Large Multipurpose Indicator Lights UpMTTF<sub>D</sub>Net Weight (Total of Emitter and Receiver) Applicable Standards: International StandardApplicable Standards: Europe (EU)Applicable Standards: JapanApplicable Standards: North AmericaOperating RangeBeam PitchMin. Sensing ObjectEffective Aperture AnglePower Voltage Control Output (OSSD)Control Output (OSSD): Operation ModeControl Output (OSSD): Protection CircuitResponse TimeLockout Output (SSD) Lockout Output (SSD): Operation ModeLockout Output (SSD): Protection Circuit Interference Prevention FunctionTest Input Function Large Multi-Purpose Indicator Function Pollution Degree Operating AltitudeEnvironmental Resistance: Degree of ProtectionAmbient TemperatureAmbient IlluminanceAmbient HumidityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementCableCable ExtensionMaterialAccessoriesDirective ComplianceEnvironmental Resistance: Dielectric Strength Voltage
Machinery Directive, EMC Directive, RoHS Directive
16
320 mm 12.598 in
Emitter: 30 mA or less
Receiver: 30 mA or less
3.86 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less
Receiver: 35 mA or less
100 years or more
(Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA
- Applied voltage: same as supply voltage (between the control output and -0V)
- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and -0V)
- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
24
480 mm 18.898 in
Emitter: 35 mA or less
Receiver: 35 mA or less
3.99 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less
Receiver: 40 mA or less
100 years or more
(Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA
- Applied voltage: same as supply voltage (between the control output and -0V)
- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and -0V)
- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
32
640 mm 25.197 in
Emitter: 35 mA or less
Receiver: 35 mA or less
4.12 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 50 mA or less
Receiver: 45 mA or less
100 years or more
(Note) Mean time to dangerous failure.
640 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA
- Applied voltage: same as supply voltage (between the control output and -0V)
- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and -0V)
- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
24
480 mm 18.898 in
Emitter: 35 mA or less
Receiver: 35 mA or less
3.85 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less
Receiver: 40 mA or less
100 years or more
(Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and +V)
- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
8
160 mm 6.299 in
Emitter: 25 mA or less
Receiver: 25 mA or less
3.60 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less
Receiver: 30 mA or less
100 years or more
(Note) Mean time to dangerous failure.
280 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and +V)
- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
12
240 mm 9.449 in
Emitter: 30 mA or less
Receiver: 30 mA or less
3.66 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less
Receiver: 35 mA or less
100 years or more
(Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and +V)
- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
12
240 mm 9.449 in
Emitter: 30 mA or less
Receiver: 30 mA or less
3.80 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less
Receiver: 35 mA or less
100 years or more
(Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA
- Applied voltage: same as supply voltage (between the control output and -0V)
- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and -0V)
- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
16
320 mm 12.598 in
Emitter: 30 mA or less
Receiver: 30 mA or less
3.73 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less
Receiver: 35 mA or less
100 years or more
(Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and +V)
- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
20
400 mm 15.748 in
Emitter: 35 mA or less
Receiver: 35 mA or less
3.93 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less
Receiver: 40 mA or less
100 years or more
(Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA
- Applied voltage: same as supply voltage (between the control output and -0V)
- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and -0V)
- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure
Machinery Directive, EMC Directive, RoHS Directive
20
400 mm 15.748 in
Emitter: 35 mA or less
Receiver: 35 mA or less
3.79 × 10-9
(Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less
Receiver: 40 mA or less
100 years or more
(Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2
(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06
(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA
- Applied voltage: same as supply voltage (between the control output and +V)
- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less
ON response: 80 to 100 ms
- Maximum sink current: 60mA
- Applied voltage: same as supply voltage (between the lockout output and +V)
- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)
- Leakage current: 200micro A or less (power supply OFF condition)
- Maximum load capacity: 2.2micro F (No load to maximum output current)
- Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout
(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less
(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
Enclosure: Polycarbonate alloy
Sensing surface: Polycarbonate alloy
MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
MS-SFC-1 (Standard mounting bracket): 1 set
SF4C-TR25 (Test rod): 1 No.
CE Marking (Machinery Directive, EMC Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification
1, 000 V AC for one min. between all supply terminals connected together and enclosure