The Ultra-Slim SF2C Light Curtains have a thickness of only 13.2mm, come in an ultra-light polycarbonate enclosure and features easy installation and reduced wiring. They are available as a hand protection type with a beam pitch of 20mm, allowing users to detect objects as small as 25mm in diameter. SF2C Light Curtains are delivered with a 3-meter cable and mounting brackets (MS-SFC-1).
Characteristics
Easy Beam Axis Alignment Due To Large Aperture Angle
Less Mounting Effort Due To Reduced Wiring
Slim Size For Compact Applications
Very Lightweight Due To Polycarbonate Enclosure
Optimum Small Width Of Only 13.2mm
Interference Prevention Output
IP67 Protection
Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C
Part number list
Results 14
Models table for series Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C
Part No.
Datasheet
CE Marking Directive Compliance
No. of Beam Channels
Protective Height
Current Consumption: Large Multipurpose Indicator Lights Off
PFHD
Current Consumption: Large Multipurpose Indicator Lights Up
MTTFD
Net Weight (Total of Emitter and Receiver)
Applicable Standards: International Standard
Applicable Standards: Europe (EU)
Applicable Standards: Japan
Applicable Standards: North America
Operating Range
Beam Pitch
Min. Sensing Object
Effective Aperture Angle
Power Voltage
Control Output (OSSD)
Control Output (OSSD): Operation Mode
Control Output (OSSD): Protection Circuit
Response Time
Lockout Output (SSD)
Lockout Output (SSD): Operation Mode
Lockout Output (SSD): Protection Circuit
Interference Prevention Function
Test Input Function
Large Multi-Purpose Indicator Function
Pollution Degree
Operating Altitude
Environmental Resistance: Degree of Protection
Ambient Temperature
Ambient Illuminance
Ambient Humidity
Insulation Resistance
Vibration Resistance
Shock Resistance
Emitting Element
Cable
Cable Extension
Material
Accessories
Directive Compliance
Environmental Resistance: Dielectric Strength Voltage
3.86 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.99 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
4.12 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 50 mA or less Receiver: 45 mA or less
100 years or more (Note) Mean time to dangerous failure.
640 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.85 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.60 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 30 mA or less
100 years or more (Note) Mean time to dangerous failure.
280 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.66 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.80 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.73 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.93 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.79 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.86 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.99 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
4.12 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 50 mA or less Receiver: 45 mA or less
100 years or more (Note) Mean time to dangerous failure.
640 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.85 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 45 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
520 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.60 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 30 mA or less
100 years or more (Note) Mean time to dangerous failure.
280 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.66 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.80 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 35 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
340 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.73 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 35 mA or less
100 years or more (Note) Mean time to dangerous failure.
400 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.93 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable
3.79 × 10-9 (Note) Probability of dangerous failure per hour.
Emitter: 40 mA or less Receiver: 40 mA or less
100 years or more (Note) Mean time to dangerous failure.
460 g approx.
IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
0.1 to 3 m 0.328 to 9.843 ft
20 mm 0.787 in
ø25 mm ø0.984 in opaque object
plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
24 V DC plus or minus 20 % Ripple P-P 10 % or less
- Maximum source current: 200mA - Applied voltage: same as supply voltage (between the control output and +V) - Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Incorporated
OFF response: 20 ms or less ON response: 80 to 100 ms
- Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and +V) - Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less
ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Incorporated
Incorporated
Incorporated
Incorporated
3
2, 000 m 6561.680 ft or less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
IP65, IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: - 25 to +60 ℃ - 13 to +140 ℉
Incandescent light: 5,000 ℓx or less at the light-receiving face
30 to 85 % RH, Storage: 30 to 85 % RH
20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
300 m / s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 850 nm 0.034 mil)
0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long
Extension up to total 50m is possible for 0.3mm2 or more, cable