Part Number List

Results 2
Models table for series Bench Top Ionizer Cleaning Box EC-B
Part No.DatasheetCE Marking Compliant DirectivesCharge Removal TimeIon balanceApplicable FluidSupplied air flowAir Pressure RangeSupply voltagePower consumptionTimer modePulse air modeAmbient TemperatureAmbient HumidityWeight (Typ.)Accessories
EMC Directive, RoHS Directive
0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V)
(Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.)
plus or minus10 V or less
Air (dried clean air)
Max. 500 liter/min. (ANR) or less
0.05 to 0.50 MPa
Accessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz
(OUTPUT: 24 V DC))
(Note:Please prepare an AC cable separately as it is needed.
The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
90 VA or less
2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch
Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch
0 to +40 ℃ +32 to +104 ℉
35 % to 65 % RH (No dew condensation)
Main body: 13 kg approx.
AC adapter: 1pc., Filter: 1pc., Protective mesh: 1pc.
EMC Directive, RoHS Directive
0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V)
(Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.)
plus or minus10 V or less
Air (dried clean air)
Max. 300 liter/min. (ANR) or less
0.05 to 0.50 MPa
Accessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz
(OUTPUT: 24 V DC))
(Note:Please prepare an AC cable separately as it is needed.
The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
80 VA or less
2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch
Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch
0 to +40 ℃ +32 to +104 ℉
35 % to 65 % RH (No dew condensation)
Main body: 6.5 kg approx.