Static Control Devices: Fan Type Ionizer ER-F

Model List

Found 4 matches. Display 1 - 4 matches.
Part No.sort descendingData SheetCE marking compliant directivesCharge removal timeIon balanceSupply voltageCurrent consumptionDischarge methodDischarge output voltageMax. fan speedMax. fan volumeMain functionsParts Inventory
   Column active Filter
Close

Filter by CE marking compliant directives

Column active Filter
Close

Filter by Charge removal time

Column active Filter
Close

Filter by Ion balance

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Discharge method

Column active Filter
Close

Filter by Discharge output voltage

Column active Filter
Close

Filter by Max. fan speed

Column active Filter
Close

Filter by Max. fan volume

Column active Filter
Close

Filter by Main functions

 
design engineersPanasonicER-F12SA
EMC Directive, RoHS Directive1.5 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC ±10%400 mA or lessHigh-frequency AC method± 2 kV approx.n/an/aError output, Discharge halt input
design engineersPanasonicER-F12A
EMC Directive, RoHS Directive1 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC ±10%700 mA or lessHigh-frequency AC method± 2 kV approx.n/an/aError output, Discharge halt input
design engineersPanasonicER-F12S
n/a1.5 sec. approx. (plus or minus1,000 V to plus or minus100 V)
(Note) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
plus or minus10 V or less
(Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC plus or minus10%400 mA or lessHigh-frequency AC methodplus or minus 2 kV approx.4.0 m/s
(Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
2.50 m3/minError output, Discharge halt input
design engineersPanasonicER-F12
n/a1 sec. approx. (plus or minus1,000 V to plus or minus100 V)
(Note) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
plus or minus10 V or less
(Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
24 V DC plus or minus10%700 mA or lessHigh-frequency AC methodplus or minus 2 kV approx.5.3 m/s
(Note) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
3.68 m3/minError output, Discharge halt input