The Data Logger Light (DLL) enables the collection and logging of target equipment and helps users realize numerous applications such as; measuring energy consumption in buildings, remote temperature control of facilities and monitoring operation log data of production lines.
Data Logger Light (DLL)
Part number list
Results 1
Models table for series Data Logger Light (DLL)
Part No.
Datasheet
Rated Operating Voltage
Allowable Operating Voltage Range
Rated Frequency
Allowable Momentary Power-Off Time
Rated Output Voltage
Output Voltage Range
Rated Output Current
Ambient Temperature
Storage Temperature
Current Consumption
Weight (Typ.)
Data Accumulation: Logged Data: Description
Data Accumulation: Logged Data: Data Format (Valid for the Register System)
Data Accumulation: Logged Data: Number of Registrable Files
Data Accumulation: Logged Data: Number of Registrable Devices
Data Accumulation: Data Saving: Saved To
Data Accumulation: Data Saving: File System
Data Accumulation: Data Saving: Saving Format
Data Accumulation: Data Saving: Number of Storable Files
85 to 264 V AC (85 to 110 % of rated operating voltage)
50 / 60 Hz
Max. 10 ms
24 V DC
21.6 V to 26.4 V DC
0.2 A (Note) If a current load over the specified level is continuously applied, the unit may break down. When a short circuit is detected, the whole power supply of Data Logger Light will be shut down.
-10 to +55 ℃ +14 to +131 ℉
-25 to +70 ℃ -13 to +158 ℉
Max. 230 mA (at 100 V AC)
Approx. 200 g (without battery)
Instantaneous, difference, average, minimum, and maximum values
16-bit integers (signed / unsigned), 32-bit integers (signed / unsigned), HEX (4-digit / 8-digit), Real number
16
300 points / 1 file (Note) The maximum total number of points for registrable devices is always 300, for either 1 file or 16 files.
Internal memory (SRAM): 1 MB SD / SDHC memory cards: 2 to 32 GB (Note) The internal memory can store data using the backup battery. Please note that data stored in the internal memory may be lost when the battery has been depleted.
VFAT / FAT / FAT32
CSV file type
100
- Constant cycle (user-selectable from 1 second to 24 hours) - Contact status (rising edge, falling edge, both edges, accumulation ON time, number of accumulation open/close operations, ON status, and OFF status) - Specified time (every minute, every hour, every day, every week, every month, every year, and specified time) - Register (=, >, <, Not =) - Trigger combinations (AND, OR)
128
LAN
Title: Within 16 one-byte or 8 two-byte characters Body: Within 256 one-byte or 128 two-byte characters
64 (with no files attached)
TCP / IP, UDP / IP
SMTP (Capable of POP / APOP authentication), FTP (client / server), SNTP, DHCP, DNS
Interface: IEEE802.3U, 10BASE-T / 100BASE-TX Connector type: RJ45 Transmission specifications (Transmission speed): 10 Mbps / 100 Mbps Transmission specifications (Transmission method): Base band Transmission specifications (Max. segment length): 100m 328ft Communication cable: UTP (category 5) Functions: Auto-negotiation function, MDI / MDI-X auto-crossover function
Interface: RS-232C (Not isolated from the internal circuit) Communication form: 1: 1 communication Number of connected units: 1 unit Communication method: Half-duplex Synchronous system: Synchronous communication method Transmission distance: 15m 49 ft Transmission speed: 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps Transmission format (Stop bit): 1-bits / 2-bits Transmission format (Parity): Odd number / Even number / Not available Transmission format (Data length): 7-bits / 8-bits(Note)With MODBUS (RTU) protocol, it works only with 8-bit. Protocol: MEWTOCOL / Modbus RTU
Interface: RS-485 (Isolated from the internal circuit) Communication form: 1: N communication Number of connected units: 99 units (Note 1)(Note 2) Communication method: Half-duplex Synchronous system: Synchronous communication method Transmission distance: Max. 1200 m 3,937 ft (Note 3) Transmission speed: 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps Transmission format (Stop bit): 1-bits / 2-bits Transmission format (Parity): Odd number / Even number / Not available Transmission format (Data length): 7-bits / 8-bits (Note 4) Protocol: MEWTOCOL / Modbus RTU (Note 1) When using a PC as a slave station, you are recommended to use SI-35 or SI-35USB of LlNEEYE Co., Ltd. as an RS485 interface. (Note 2) When using SI-35,SI-35USB, our Eco-POWER METER or our PLC (which can be connected up to 99 units), up to 99 units can be connected. In case using this system with the other devices, up to 31 units can be connected. (Note 3) The transmission distance is limited by the transmission speed and the number of units connected. When the speed is 38,400 bps or lower, the maximum transmission distance is 1,200 m 3,937 ft, and the number of units is 99. (Note 4) With Modbus RTU protocol, it works only with 8-bit.
SD / SDHC standard conformance (Note) UHS standard SDHC memory cards are not supported. Log data may not be written to the SD memory card if an SD memory card without operational confirmation is used.
2 to 32 GB
Models table for series Data Logger Light (DLL)
Part No.
Datasheet
Rated Operating Voltage
Allowable Operating Voltage Range
Rated Frequency
Allowable Momentary Power-Off Time
Rated Output Voltage
Output Voltage Range
Rated Output Current
Ambient Temperature
Storage Temperature
Current Consumption
Weight (Typ.)
Data Accumulation: Logged Data: Description
Data Accumulation: Logged Data: Data Format (Valid for the Register System)
Data Accumulation: Logged Data: Number of Registrable Files
Data Accumulation: Logged Data: Number of Registrable Devices
Data Accumulation: Data Saving: Saved To
Data Accumulation: Data Saving: File System
Data Accumulation: Data Saving: Saving Format
Data Accumulation: Data Saving: Number of Storable Files
85 to 264 V AC (85 to 110 % of rated operating voltage)
50 / 60 Hz
Max. 10 ms
24 V DC
21.6 V to 26.4 V DC
0.2 A (Note) If a current load over the specified level is continuously applied, the unit may break down. When a short circuit is detected, the whole power supply of Data Logger Light will be shut down.
-10 to +55 ℃ +14 to +131 ℉
-25 to +70 ℃ -13 to +158 ℉
Max. 230 mA (at 100 V AC)
Approx. 200 g (without battery)
Instantaneous, difference, average, minimum, and maximum values
16-bit integers (signed / unsigned), 32-bit integers (signed / unsigned), HEX (4-digit / 8-digit), Real number
16
300 points / 1 file (Note) The maximum total number of points for registrable devices is always 300, for either 1 file or 16 files.
Internal memory (SRAM): 1 MB SD / SDHC memory cards: 2 to 32 GB (Note) The internal memory can store data using the backup battery. Please note that data stored in the internal memory may be lost when the battery has been depleted.
VFAT / FAT / FAT32
CSV file type
100
- Constant cycle (user-selectable from 1 second to 24 hours) - Contact status (rising edge, falling edge, both edges, accumulation ON time, number of accumulation open/close operations, ON status, and OFF status) - Specified time (every minute, every hour, every day, every week, every month, every year, and specified time) - Register (=, >, <, Not =) - Trigger combinations (AND, OR)
128
LAN
Title: Within 16 one-byte or 8 two-byte characters Body: Within 256 one-byte or 128 two-byte characters
64 (with no files attached)
TCP / IP, UDP / IP
SMTP (Capable of POP / APOP authentication), FTP (client / server), SNTP, DHCP, DNS
Interface: IEEE802.3U, 10BASE-T / 100BASE-TX Connector type: RJ45 Transmission specifications (Transmission speed): 10 Mbps / 100 Mbps Transmission specifications (Transmission method): Base band Transmission specifications (Max. segment length): 100m 328ft Communication cable: UTP (category 5) Functions: Auto-negotiation function, MDI / MDI-X auto-crossover function
Interface: RS-232C (Not isolated from the internal circuit) Communication form: 1: 1 communication Number of connected units: 1 unit Communication method: Half-duplex Synchronous system: Synchronous communication method Transmission distance: 15m 49 ft Transmission speed: 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps Transmission format (Stop bit): 1-bits / 2-bits Transmission format (Parity): Odd number / Even number / Not available Transmission format (Data length): 7-bits / 8-bits(Note)With MODBUS (RTU) protocol, it works only with 8-bit. Protocol: MEWTOCOL / Modbus RTU
Interface: RS-485 (Isolated from the internal circuit) Communication form: 1: N communication Number of connected units: 99 units (Note 1)(Note 2) Communication method: Half-duplex Synchronous system: Synchronous communication method Transmission distance: Max. 1200 m 3,937 ft (Note 3) Transmission speed: 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 115,200 bps Transmission format (Stop bit): 1-bits / 2-bits Transmission format (Parity): Odd number / Even number / Not available Transmission format (Data length): 7-bits / 8-bits (Note 4) Protocol: MEWTOCOL / Modbus RTU (Note 1) When using a PC as a slave station, you are recommended to use SI-35 or SI-35USB of LlNEEYE Co., Ltd. as an RS485 interface. (Note 2) When using SI-35,SI-35USB, our Eco-POWER METER or our PLC (which can be connected up to 99 units), up to 99 units can be connected. In case using this system with the other devices, up to 31 units can be connected. (Note 3) The transmission distance is limited by the transmission speed and the number of units connected. When the speed is 38,400 bps or lower, the maximum transmission distance is 1,200 m 3,937 ft, and the number of units is 99. (Note 4) With Modbus RTU protocol, it works only with 8-bit.
SD / SDHC standard conformance (Note) UHS standard SDHC memory cards are not supported. Log data may not be written to the SD memory card if an SD memory card without operational confirmation is used.