External Input Unit for Digital Sensor FX-CH2

The Panasonic External Input Unit For Digital Sensor FX-CH2 will allow external access for teaching, data bank switching and other functionality.          
                                 
Characteristics:

  • External Input Unit Can Monitor And Change Setting Up To 16 Sensors
  • External Teaching Can Be Done For Stable Sensing Applications.(Glass Substrates Or Sensing In Poor Environments)
  • Data Bank Switching And Key Lock Function Can Both Be Performed
  • Any PLC Or Touch Can Be Used Remotely To Perform Operations

Part Number List

Results 2
Models table for series External Input Unit for Digital Sensor FX-CH2
Part No.DatasheetApplicable SensorsSupply Voltage Power ConsumptionInputPower Indicator Transmission Operation IndicatorAmbient TemperatureMaterialConnecting MethodAccessoryWeight (Typ.)
FX-301(P) (Note) , FX-305(P)
(Note) Only updated version of FX-301(P) can be used. Do not use the previous version of FX-301(P). The updated version of FX-301(P) have ''NAVI'' printed on one side.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
600 mW or less (when all indicators light up)
Low: 0 to +2 V DC
Source current 0.5 mA
Input impedance 10 kOhm approx.
High: +5 V to +V DC, or open
Green LED (Lights up when the power is ON)
Green LED (Lights up when loaded, and 2-level / Limit teaching, blinks to lights up when saved, and Full-auto teaching)
-10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 sensors are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 sensors are connected in cascade: -10 to +45 degrees +14 to +113 degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Enclosure: Heat-resistant ABS
Connector
(Note) The cable for unit connection is not supplied as an accessory. Be sure to use the optional quick-connection cables given below.
Main cable (3-core)
CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
CN-EP1 (Connector for input device) (Note) : 1 pc.
(Note) The applicable wire is 0.08 mm2 (AWG 28) to 0.5 mm2 (AWG 20) and the wire sheath diameter should be dia. 1.5 mm dia. 0.059 in or less.
Net weight: 20 g approx.
Gross weight: 40 g approx.
FX-301(P) (Note) , FX-305(P)
(Note) Only updated version of FX-301(P) can be used. Do not use the previous version of FX-301(P). The updated version of FX-301(P) have ''NAVI'' printed on one side.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
600 mW or less (when all indicators light up)
High: +4 V to +V DC
Sink current 0.5 to 3 mA
Input impedance 10 kOhm approx.
Low: 0 to +0.6 V DC, or open
Green LED (Lights up when the power is ON)
Green LED (Lights up when loaded, and 2-level / Limit teaching, blinks to lights up when saved, and Full-auto teaching)
-10 to +55 degrees +14 to +131 degrees Fahrenheit (If 4 to 7 sensors are connected in cascade: -10 to +50 degrees +14 to +122 degrees Fahrenheit , if 8 to 16 sensors are connected in cascade: -10 to +45 degrees +14 to +113 degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Enclosure: Heat-resistant ABS
Connector
(Note) The cable for unit connection is not supplied as an accessory. Be sure to use the optional quick-connection cables given below.
Main cable (3-core)
CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
CN-EP1 (Connector for input device) (Note) : 1 pc.
(Note) The applicable wire is 0.08 mm2 (AWG 28) to 0.5 mm2 (AWG 20) and the wire sheath diameter should be dia. 1.5 mm dia. 0.059 in or less.
Net weight: 20 g approx.
Gross weight: 40 g approx.