Specification

Specifications table for model HG-S1010
ItemPerformance characteristics
CE Marking Directive ComplianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Applicable ControllerHG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
Position Detection Method Optical absolute linear encoder method
Measuring Range10 mm 0.394 in
Travel (mm)10.5 mm 0.413 in or more
Measuring Force: Downward Mount1.65 N or less
1.10 N
(Note): Typical value near center of measurement.
Measuring Force: Upward Mount1.35 N or less
0.85 N
(Note): Typical value near center of measurement.
Measuring Force: Side Mount 1.50 N or less
0.95 N
(Note): Typical value near center of measurement.
Resolution0.5 μm 0.020 mil
Sampling Rate1ms
Indication Accuracy (P-P)Full range: 2.0 μm 0.079 mil or less
Narrow range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
Tip Deviation Amount35 μm 1.378 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.
Hot Swap FunctionIncorporated
Operation Indicator 2-color LED (Orange / Green)
Environmental Resistance: ProtectionIP67 (IEC)
(Note): Excludes damage and deterioration to rubber bellows due to external causes.
Environmental Resistance: Ambient Temperature-10 to +55 ℃ +14 to +131 ℉
(No condensation or icing),
Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental Resistance: Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Insulation Resistance100 MΩ or more at 250 V DC
Environmental Resistance: Vibration Resistance10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each
Environmental Resistance: Shock Resistance1,960 m/s2acceleration in X, Y and Z directions three times each
Mounting Nut Tightening Strength12.5N・m
Probe Tightening Torque 0.1 to 0.4 N・m (no force applied to main unit)
Grounding MethodCapacitor grounding
MaterialBody: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe: Brass (body) / Ceramic (ball), Rubber bellows: NBR (black)
※The probes (optional) are also available.
Weight (Typ.)Net weight: 80 g approx.
AccessoryStandard type (HG-S1010 / HG-S1110): Sensor head fastening wrench 1 pc., Mounting nut 1 pc.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃ +68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment.
Pollution Degree 2
Operating Altitude2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.