Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Applicable Controller | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 |
Position Detection Method | Optical absolute linear encoder method |
Measuring Range | 10 mm 0.394 in |
Travel (mm) | 10.5 mm 0.413 in or more |
Measuring Force: Downward Mount | 0.35 N or less 0.30 N (Note 1): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows. (Note 2): Typical value near center of measurement. |
Measuring Force: Upward Mount | - |
Measuring Force: Side Mount | 0.25 N or less 0.20 N (Note 1): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows. (Note 2): Typical value near center of measurement. |
Resolution | 0.1 μm 0.004 mil |
Sampling Rate | 1ms |
Indication Accuracy (P-P) | Full range: 1.0 μm 0.039 mil or less Narrow range: 0.5 μm 0.020 mil or less (any 60 μm 2.362 mil) |
Tip Deviation Amount | 35 μm 1.378 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values. |
Hot Swap Function | Incorporated |
Operation Indicator | 2-color LED (Orange / Green) |
Environmental Resistance: Protection | - |
Environmental Resistance: Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental Resistance: Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation Resistance | 100 MΩ or more at 250 V DC |
Environmental Resistance: Vibration Resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each |
Environmental Resistance: Shock Resistance | 1,960 m/s2acceleration in X, Y and Z directions three times each |
Mounting Nut Tightening Strength | 12.5N・m |
Probe Tightening Torque | 0.1 to 0.4 N・m (no force applied to main unit) |
Grounding Method | Capacitor grounding |
Material | Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe※: Brass (body) / Ceramic (ball), Rubber bellows: NBR (black) ※The probes (optional) are also available. |
Weight (Typ.) | Net weight: 80 g approx. |
Accessory | Low measuring force type (HG-S1010R / HG-S1110R): Sensor head fastening wrench 1 pc., Mounting nut 1 pc., Rubber bellows 1 pc. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃ +68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment. |
Pollution Degree | 2 |
Operating Altitude | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
The service is owned, operated, controlled and managed by Panasonic's distributors.