Specifications

Specifications table for model HG-SC101-P
ItemPerformance characteristics
CE Marking Directive ComplianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Environmental Resistance: ProtectionIP40 (IEC)
Environmental Resistance: Ambient Temperature-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental Resistance: Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Insulation Resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental Resistance: Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental Resistance: Shock Resistance98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
MaterialCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Weight (Typ.)Net weight:
140 g approx.
RemarkWhere measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
.Compatible Sensor HeadHG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
Supply Voltage 24 V DC ±10 %, including ripple 0.5 V (P-P)
Number of Connectable UnitsUp to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Current Consumption70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
Analog Current Output• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.
Control Outputs (Output 1, Output 2, Output 3)
NPN open-collector transistor
• Maximum sink current: 50 mA(Note 5))
• Applied voltage: 30 V DC or less(between output and 0 V)
• Residual voltage: 1.5 V or less(at 50 mA sink current)
• Leakage current: 0.1 mA or less

>
PNP open-collector transistor
• Maximum source current: 50 mA(Note 5)
• Applied voltage: 30 V DC or less(between output and +V)
• Residual voltage: 1.5 V or less(at 50 mA source current)
• Leakage current: 0.1 mA or less
Control Outputs (Output 1, Output 2, Output 3): Short-Circuit ProtectionIncorporated (automatic reset type)
Control Outputs (Output 1, Output 2, Output 3): Judgment OutputNO / NC switching method
Control Outputs (Output 1, Output 2, Output 3): Alarm Output Open when alarm occurs
External Inputs (Input 1, Input 2, Input 3)
Non-contact input or NPN open-collector transistor
• Input condition:
Invalid (+8 V to +V DC or open)
Valid (0 to +1.2 V DC)
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
• Input condition:
Invalid (0 to +0.6 V DC or open)
Valid (+4 V to +V DC)
• Input impedance: 10 kΩ approx.
External Inputs (Input 1, Input 2, Input 3): Trigger InputInput time 2 ms or more (ON)
External Inputs (Input 1, Input 2, Input 3): Preset InputInput time 20 ms or more (ON)
External Inputs (Input 1, Input 2, Input 3): Reset InputInput time 20 ms or more (ON)
External Inputs (Input 1, Input 2, Input 3) Bank Input A/BInput time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
Response Time3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
Digital Display204-segment LCD
Display Resolution0.1μm 0.004 mil
Display Range-199.9999 to 199.9999mm -7.874 to 7.874 in
Contamination Level2
Elevation2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental Resistance: Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Cable0.2 mm2 2-core cable (brown and blue lead wires) / 0.15 mm2 7‑core composite cable, 2 m 6.562 ft long
NotesWhere measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
Pollution Degree 2
Operating Altitude2000 m 6561.68 ft or less

Stock check

Model image for HG-SC101-P

HG-SC101-P