Specifications
Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Environmental Resistance: Protection | IP40 (IEC) |
Environmental Resistance: Ambient Temperature | -10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental Resistance: Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation Resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Environmental Resistance: Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each |
Environmental Resistance: Shock Resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
Weight (Typ.) | Net weight: 130 g approx. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉. |
.Compatible Sensor Head | HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050 |
Supply Voltage | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
Number of Connectable Units | Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
Current Consumption | 70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output. |
Analog Current Output | - |
Control Outputs (Output 1, Output 2, Output 3) | NPN open-collector transistor • Maximum sink current: 50 mA(Note 5)) • Applied voltage: 30 V DC or less(between output and 0 V) • Residual voltage: 1.5 V or less(at 50 mA sink current) • Leakage current: 0.1 mA or less PNP open-collector transistor • Maximum source current: 50 mA(Note 5) • Applied voltage: 30 V DC or less(between output and +V) • Residual voltage: 1.5 V or less(at 50 mA source current) • Leakage current: 0.1 mA or less |
Control Outputs (Output 1, Output 2, Output 3): Short-Circuit Protection | Incorporated (automatic reset type) |
Control Outputs (Output 1, Output 2, Output 3): Judgment Output | NO / NC switching method |
Control Outputs (Output 1, Output 2, Output 3): Alarm Output | Open when alarm occurs |
External Inputs (Input 1, Input 2, Input 3) | Non-contact input or NPN open-collector transistor • Input condition: Invalid (+8 V to +V DC or open) Valid (0 to +1.2 V DC) •Input impedance: 10 kΩ approx. Non-contact input or PNP open-collector transistor • Input condition: Invalid (0 to +0.6 V DC or open) Valid (+4 V to +V DC) • Input impedance: 10 kΩ approx. |
External Inputs (Input 1, Input 2, Input 3): Trigger Input | Input time 2 ms or more (ON) |
External Inputs (Input 1, Input 2, Input 3): Preset Input | Input time 20 ms or more (ON) |
External Inputs (Input 1, Input 2, Input 3): Reset Input | Input time 20 ms or more (ON) |
External Inputs (Input 1, Input 2, Input 3) Bank Input A/B | Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B. |
Response Time | 3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type |
Digital Display | 204-segment LCD |
Display Resolution | 0.1μm 0.004 mil |
Display Range | -199.9999 to 199.9999mm -7.874 to 7.874 in |
Contamination Level | 2 |
Elevation | 2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental Resistance: Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Cable | 0.15 mm2, 6‑core composite cable, 2 m 6.562 ft long |
Notes | Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉. |
Pollution Degree | 2 |
Operating Altitude | 2000 m 6561.68 ft or less |
Stock check
HG-SC112-P