Ultra-compact Laser Collimated Beam Sensor HL-T1

The HL-T1 Sensor is an ultra-small laser Thru-Beam Sensor with very high resolution.

Three different types are available: HL-T1001F with a 1mm laser beam which is able to detect object 8µm in diameter at a distance of 500mm between receiver and transmitter; HL-T1005F and HL-T1010F with a laser collimator which produces a light curtain of 5mm or 10mm width respectively. The red Semiconductor LED, which belongs to Laser Class 1, makes it possible to use HL-T1 without any safety requirements.

Characteristics

  • Resolution Max. 4µm
  • Red Light Semiconductor LED Belongs To Laser Class 1
  • Sensing Range Up To 2m (HL-T1001F)
  • Minimum Sensing Object 8µm Diameter (HL-T1001AF)
  • Compact Design

Part Number List

Results 8
Models table for series Ultra-compact Laser Collimated Beam Sensor HL-T1
Part No.DatasheetTypeCE Marking Directive ComplianceApplicable ControllerSensing Range Emission IndicatorInterference Prevention FunctionApplicable Sensor HeadSupply Voltage Current ConsumptionMeasuring CycleLinear OutputLinear Output: Temperature CharacteristicsSettable Average Sampling Rate Judgment Outputs (HIGH, PASS, LOW)Judgment Outputs (HIGH, PASS, LOW): Utilization Category Judgment Outputs (HIGH, PASS, LOW): Number of OutputsJudgment Outputs (HIGH, PASS, LOW): Output OperationJudgment Outputs (HIGH, PASS, LOW): Short-Circuit ProtectionLaser Off InputZero Reset InputTiming InputReset Input Indicators: Laser Emitting (LD ON)Indicators: Judgment OutputsIndicators: Enable Indicators: Zero Reset (Zero) Main Digital DisplaySub-Digital DisplayMain FunctionsPollution Degree Environmental Resistance: Ambient TemperatureEnvironmental Resistance: Ambient HumidityEnvironmental Resistance: Ambient IlluminanceVoltage WithstandabilityInsulation ResistanceEnvironmental Resistance: Vibration ResistanceEnvironmental Resistance: Shock ResistanceEmitting Element: IEC/JIS Standards Conforming TypeEmitting Element: FDA Regulations Conforming TypeMaterialCableCable ExtensionI/O CableI/O Cable ExtensionWeight (Typ.)Accessory
Beam diameter dia.1 mm dia.0.039 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 15 g approx.
Receiver: 15 g approx.
MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1(Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set
Sensing width 10 mm 0.394 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 30 g approx.
Receiver: 20 g approx.
MS-LA3-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1 (Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set
Sensing width 5 mm 0.197 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 15 g approx.
Receiver: 15 g approx.
MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1(Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set
PNP output
EMC Directive, RoHS Directive
HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
190 mA or less (when connected to the sensor head)
150 micro s
Current / voltage output switchable (Note)
-During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ohm
-During voltage output: plus or minus 4 V/F.S., Output impedance 100 Ohm
(In the monitor focus function, it can also be set at plus or minus 5 V, 0 to 5 V, etc.)
(Note) Switching between current and voltage is accomplished by a switch on the bottom of the controller.
plus or minus 0.2 % F.S./℃
(Note) These are the temperature characteristics of the linear output when the sensor head is connected.
1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096
(Note) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1).
PNP open-collector transistor
-Maximum source current: 50 mA
-Applied voltage: 30 V DC or less (between judgment output and +V)
-Residual voltage: 2 V or less (at 50 mA source current)
DC-12 or DC-13
HIGH / PASS / LOW 3 values output
HIGH: ON when measured value > HIGH threshold value
PASS: ON when HIGH threshold value >= measured value >= LOW threshold value
LOW: ON when LOW threshold value > measured value
Incorporated
+V connection: Laser emission halt
Open: Laser emission
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
+V connection: Zero reset operates
Open: Zero reset ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
+V connection: Effective
Open: Ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
+V connection: Effective
Open: Ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Green LED (lights up during laser emission)
HIGH: Orange LED (lights up when measured value > HIGH threshold value)
PASS: Green LED (lights up when HIGH threshold value >= measured value >= LOW threshold value)
LOW: Yellow LED (lights up when LOW threshold value > measured value)
Green LED (lights up during normal operation)
Green LED (lights up when the zero reset function is enabled)
5 digit red LED display
[RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.]
5 digit yellow LED display
[RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.]
・Measured value display
・Setting value, light amount value resolution display
・Standard received light setting
・Automatic scaling
・Scaling
・Display reverse
・ECO display
・Display digits limitation
・Sample hold
・Peak hold
・Bottom hold
・Peak to peak hold
・Self peak hold
・Self bottom hold
・Zero reset
・Initial reset
・ON-delay timer
・OFF-delay timer
・One-shot timer
・Differentiation
・Sensitivity selection
・Threshold value direct setting
・Positioning teaching
・2-point teaching
・Automatic teaching
・Hysteresis width variability
・Monitor focus
・Non-measuring time setting
・(A – B) calculation(Note:The calculation unit is necessary.)
・(A + B) calculation(Note:The calculation unit is necessary.)
・Mutual interference prevention (Note:The calculation unit is necessary.)
・Laser deterioration detection
・Key lock
・Zero reset memory
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min.
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Enclosure: Polybutylene terephthalate
Transparent cover: Polycarbonate
0.09 mm2 10-core composite cable, 2 m 6.562 ft long
Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable.
(Note) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking.
Net weight: 140 g approx.
NPN output
EMC Directive, RoHS Directive
HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
190 mA or less (when connected to the sensor head)
150 micro s
Current / voltage output switchable (Note)
-During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ohm
-During voltage output: plus or minus 4 V/F.S., Output impedance 100 Ohm
(In the monitor focus function, it can also be set at plus or minus 5 V, 0 to 5 V, etc.)
(Note) Switching between current and voltage is accomplished by a switch on the bottom of the controller.
plus or minus 0.2 % F.S./℃
(Note) These are the temperature characteristics of the linear output when the sensor head is connected.
1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096
(Note) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1).
NPN open-collector transistor
-Maximum sink current: 50 mA
-Applied voltage: 30 V DC or less (between judgment output and 0 V)
-Residual voltage: 1.2 V or less (at 50 mA sink current)
DC-12 or DC-13
HIGH / PASS / LOW 3 values output
HIGH: ON when measured value > HIGH threshold value
PASS: ON when HIGH threshold value >= measured value >= LOW threshold value
LOW: ON when LOW threshold value > measured value
Incorporated
0 V connection: Laser emission halt
Open: Laser emission
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
0 V connection: Zero reset operates
Open: Zero reset ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
0 V connection: Effective
Open: Ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
0 V connection: Effective
Open: Ineffective
-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)
Green LED (lights up during laser emission)
HIGH: Orange LED (lights up when measured value > HIGH threshold value)
PASS: Green LED (lights up when HIGH threshold value >= measured value >= LOW threshold value)
LOW: Yellow LED (lights up when LOW threshold value > measured value)
Green LED (lights up during normal operation)
Green LED (lights up when the zero reset function is enabled)
5 digit red LED display
[RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.]
5 digit yellow LED display
[RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.]
・Measured value display
・Setting value, light amount value resolution display
・Standard received light setting
・Automatic scaling
・Scaling
・Display reverse
・ECO display
・Display digits limitation
・Sample hold
・Peak hold
・Bottom hold
・Peak to peak hold
・Self peak hold
・Self bottom hold
・Zero reset
・Initial reset
・ON-delay timer
・OFF-delay timer
・One-shot timer
・Differentiation
・Sensitivity selection
・Threshold value direct setting
・Positioning teaching
・2-point teaching
・Automatic teaching
・Hysteresis width variability
・Monitor focus
・Non-measuring time setting
・(A – B) calculation(Note:The calculation unit is necessary.)
・(A + B) calculation(Note:The calculation unit is necessary.)
・Mutual interference prevention (Note:The calculation unit is necessary.)
・Laser deterioration detection
・Key lock
・Zero reset memory
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min.
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Enclosure: Polybutylene terephthalate
Transparent cover: Polycarbonate
0.09 mm2 10-core composite cable, 2 m 6.562 ft long
Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable.
(Note) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking.
Net weight: 140 g approx.
Sensing width 5 mm 0.197 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 15 g approx.
Receiver: 15 g approx.
MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1(Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set
Sensing width 10 mm 0.394 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 30 g approx.
Receiver: 20 g approx.
MS-LA3-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1 (Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set
Beam diameter dia.1 mm dia.0.039 in type
EMC Directive, RoHS Directive
HL-AC1, HL-AC1P
■■【In the case of(0 to 500 mm 0 to 19.685 in)】■■
Sensing width:
ø1 mm ø0.039 in

Min. sensing object:
ø8 micro m ø0.315 mil opaque object

Repeatability (During the state in which light is half blocked):
4 micro m 0.157 mil
(Note:In case of an average sampling rate of 64 times.)

Linear output resolution:
4 micro m 0.157 mil
(Note) In case of an average sampling rate of 64 times.
(Note)Value calculated with the linear output allowance factor (plus or minus 3 sigma) when connected to the controller included in the calculation of the detection width.
(Note:This value was obtained by converting the range of linear output fluctuation (plus or minus 3 sigma) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.)


■■【In the case of (500 to 2,000 mm 19.685 to 78.74 in)】■■
Sensing width:
ø1 to ø2.5 mm ø0.039 to ø0.098 in

Min. sensing object:
ø50 micro m ø1.969 mil opaque object
Repeatability (During the state in which light is half blocked): -

Linear output resolution: -
-
Green LED (lights up during laser emission)
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)
3 (industrial environment)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -25 to +65 ℃ -13 to +149 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 10,000 liter x or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS)
(modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil)
Red semiconductor laser Class II (FDA)
(modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil)
(IEC / JIS: Class 1)
Enclosure: Polyetherimide
Case cover: Polycarbonate
Front cover: Glass
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long
Extension up to total 10 m 32.808 ft is possible, with the optional cable.
Emitter: 15 g approx.
Receiver: 15 g approx.
MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver
CN-HLT1-1(Sensor head to controller connection cable): 1 cable
Laser beam alignment sticker: 2 pcs.
Label set (FDA regulations conformed type only): 1 set

What's New

Stay up to date