High Speed・High Accuracy Eddy Current Type Digital Displacement Sensor GP-X

GP-X INDUCTIVE ANALOG SENSORS (CONTROLLER)

The inductive displacement transducers of the GP-X Series use eddy current techniques and are particularly noted for their highly accurate measurement at a resolution of 0.02% F.S. with minimal linearity error, a high sampling frequency of 40kHz and low temperature dependence. 

GP-X Series Sensors are ideally suitable for the highly accurate motion and distance control of metal objects in harsh industrial environments.

Characteristics 

  • High Sampling Frequency Of 40kHz 
  • Resolution Of 0.02% F.S. 
  • Minimal Linearity Error Max. ±0.3% F.S. 
  • Minimal Temperature Dependence Max. ±0.07% F.S./°C 
  • Bright, Two-Color LCD Display 
  • Pre-Selectable Materials (Aluminum, Steel, Iron) 
  • Four (4) Pre-Selectable Measurement Modes
  • Cross Talk Prevention Function 
  • Offset Compensation And Scaling Functions 
  • Synchronization Input And Alarm Output 
  • Adjustable Limit Values With Transistor Outputs 

Part Number List

Results 18
Models table for series High Speed・High Accuracy Eddy Current Type Digital Displacement Sensor GP-X
Part No.DatasheetTypeCE Marking Directive ComplianceSupply Voltage Current ConsumptionResolutionSampling FrequencyLinearityTemperature Characteristics Analog Voltage OutputsAnalog Voltage Outputs: Response TimeComparative Outputs (HI, GO, LO)Comparative Outputs (HI, GO, LO): Utilization CategoryComparative Outputs (HI, GO, LO): Output NumberComparative Outputs (HI, GO, LO): Output OperationComparative Outputs (HI, GO, LO): Short-Circuit ProtectionExternal InputSerial I/OZero-Set Setting MethodIndicators: ModeIndicators: HIIndicators: GOIndicators: LO Indicators: TimingUpper Level Digital Display PartLower Level Digital Display PartPollution Degree Ambient TemperatureAmbient Humidity Vibration ResistanceShock ResistanceMaterialWeight (Typ.)AccessorySensing RangeProtectionStandard Sensing ObjectVoltage WithstandabilityInsulation ResistanceCK ResistanceEnclosureCable ProtectorSensing Part CableCable ExtensionAccessoriesNet Weight
Non-threaded type For 0.8 mm 0.031 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.04 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
NPN open-collector transistor
-Maximum sink current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and 0 V)
-Residual voltage: 1.6 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between +24 V and input), OFF voltage 4 V or less (between +24 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 0.8 mm 0 to 0.031 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
-
ABS
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
-
40 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Non-threaded type For 0.8 mm 0.031 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.04 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
PNP open-collector transistor
-Maximum source current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and +V)
-Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 0.8 mm 0 to 0.031 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
-
ABS
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
-
40 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Threaded type For 10 mm 0.394 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.02 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
PNP open-collector transistor
-Maximum source current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and +V)
-Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 10 mm 0 to 0.394 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Brass (Nickel plated)
PP
PA
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
80 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Threaded type For 10 mm 0.394 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.02 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
NPN open-collector transistor
-Maximum sink current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and 0 V)
-Residual voltage: 1.6 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between +24 V and input), OFF voltage 4 V or less (between +24 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 10 mm 0 to 0.394 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Brass (Nickel plated)
PP
PA
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
80 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Threaded type For 2 mm 0.079 in sensing
EMC Directive, RoHS Directive
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
0 to 2 mm 0 to 0.079 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
PP
ABS
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
50 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Threaded type For 5 mm 0.197 in sensing
EMC Directive, RoHS Directive
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
0 to 5 mm 0 to 0.197 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Brass (Nickel plated)
PP
PA
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
45 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Threaded type For 5 mm 0.197 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.02 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
PNP open-collector transistor
-Maximum source current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and +V)
-Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 5 mm 0 to 0.197 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Brass (Nickel plated)
PP
PA
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
Nut: 2 pcs.
Toothed lock washer: 1 pc.
45 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Non-threaded type For 1 mm 0.039 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.04 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
PNP open-collector transistor
-Maximum source current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and +V)
-Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 1 mm 0 to 0.039 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
PP
PAR
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
-
40 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Non-threaded type For 2 mm 0.079 in sensing
EMC Directive, RoHS Directive
24 V DC plus or minus 10 % Ripple P-P 10 % or less
150 mA or less
0.02 % F.S. (64 times average processing)
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
40 kHz (25 micro s)
Within plus or minus 0.3 % F.S.
(Note) This value was obtained at a constant +25 ℃ +77 ℉ .
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2)
(Note1: Adjusted to a 0 to +5 V factory setting.)
(Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.)
75 micro s (maximum speed)
PNP open-collector transistor
-Maximum source current: 100 mA
-Applied voltage: 30 V DC or less
(between comparative output and +V)
-Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
HI / GO / LO 3 value output
HI: ON when measured value > the upper limit value
GO: ON when upper limit value >= measured value >= lower limit value
LO: ON when lower limit value > measured value
Incorporated
Photo-coupler input
- Input current: 9 mA or less
- Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input)
- Input impedance: 5 kΩ approx.
RS-232C
Push button setting / External input setting
Orange LED (lights up when in mode status)
Orange LED (lights up when the upper limit value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Polycarbonate
Net weight: 120 g approx.
ATA4811 (Controller mounting frame): 1 set
0 to 2 mm 0 to 0.079 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
PP
ABS
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
-
40 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Non-threaded type For 1 mm 0.039 in sensing
EMC Directive, RoHS Directive
0.07 % F.S./℃ or less
(Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
3 (Industrial environment)
-10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
0 to 1 mm 0 to 0.039 in
(Note) The sensing range is specified for the standard sensing object.
IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
250 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Stainless steel (SUS303)
PP
PAR
High frequency coaxial cable with connector, 3 m 9.843 ft long
(Note) For the flexible cable type, please contact our office.
Extension up to total 10 m 32.808 ft is possible with the optional cable.
-
40 g approx.
(Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.