| | | | | | | | Orange LED (lights up when output 1 and output 2 are ON) | Green LED (lights up during laser emission) | | | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: -10 to +50 ℃ +14 to +122 ℉ , if 8 to 16 units are mounted close together: -10 to +45 ℃ +14 to +113 ℉ ) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | | | Enclosure: Heat-resistant ABS Transparent cover: Polycarbonate Push button switch: Acrylic Jog switch: ABS | 0.15 mm2 5-core cabtyre cable, 2 m 6.562 ft long | Net weight: 65 g approx Gross weight: 75 g approx | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) | NPN open-collector transistor - Maximum sink current: 100 mA (Note) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less [at 100 mA (Note) sink current] (Note) 50 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. | Selectable either Light-ON or Dark-ON, with jog switch | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch | Incorporated | NPN non-contact input - Signal condition High: +5 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less) - Input impedance: 10 kOhm approx. | Yellow LED (lights up when either output 1 or output 2 is selected) | RUN: Green LED TEACH, L/D, TIMER, CUST, PRO: Yellow LED | 4 digit (green) + 4 digit (red) LED display | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustment Window comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Hysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Differential mode: 5-level settings | Incorporated | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. | 1 to 9,999 ms | Incorporated [Up to four sets of sensor heads can be mounted close together. (However, disabled when in H-SP mode)] | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
| | | | | | | | Orange LED (lights up when output 1 and output 2 are ON) | Green LED (lights up during laser emission) | | | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: -10 to +50 ℃ +14 to +122 ℉ , if 8 to 16 units are mounted close together: -10 to +45 ℃ +14 to +113 ℉ ) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | | | Enclosure: Heat-resistant ABS Transparent cover: Polycarbonate Push button switch: Acrylic Jog switch: ABS | - (Note) The cable is not supplied as an accessory. Be sure to use the optional quick-connection cables given below. Main cable (4-core): CN-74-C1 (cable length 1 m 3.281 ft), CN-74-C2 (cable length 2 m 6.562 ft), CN-74-C5 (cable length 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length 1 m 3.281 ft), CN-72-C2 (cable length 2 m 6.562 ft), CN-72-C5 (cable length 5 m 16.404 ft) | Net weight: 15 g approx Gross weight: 20 g approx | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) | NPN open-collector transistor - Maximum sink current: 100 mA (Note) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less [at 100 mA (Note) sink current] (Note) 50 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. | Selectable either Light-ON or Dark-ON, with jog switch | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch | Incorporated | - | Yellow LED (lights up when either output 1 or output 2 is selected) | RUN: Green LED TEACH, L/D, TIMER, CUST, PRO: Yellow LED | 4 digit (green) + 4 digit (red) LED display | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustment Window comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Hysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Differential mode: 5-level settings | Incorporated | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. | 1 to 9,999 ms | Incorporated [Up to four sets of sensor heads can be mounted close together. (However, disabled when in H-SP mode)] | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 30 to 1,000 mm 1.181 to 39.370 in | 30 to 500 mm 1.181 to 19.685 in | 30 to 300 mm 1.181 to 11.811 in | 30 to 300 mm 1.181 to 11.811 in | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | Multi-turn adjuster | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 40 g approx | Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |
| | | | | | | | Orange LED (lights up when output 1 and output 2 are ON) | Green LED (lights up during laser emission) | | | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: -10 to +50 ℃ +14 to +122 ℉ , if 8 to 16 units are mounted close together: -10 to +45 ℃ +14 to +113 ℉ ) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | | | Enclosure: Heat-resistant ABS Transparent cover: Polycarbonate Push button switch: Acrylic Jog switch: ABS | - (Note) The cable is not supplied as an accessory. Be sure to use the optional quick-connection cables given below. Main cable (4-core): CN-74-C1 (cable length 1 m 3.281 ft), CN-74-C2 (cable length 2 m 6.562 ft), CN-74-C5 (cable length 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length 1 m 3.281 ft), CN-72-C2 (cable length 2 m 6.562 ft), CN-72-C5 (cable length 5 m 16.404 ft) | Net weight: 15 g approx Gross weight: 20 g approx | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) | NPN open-collector transistor - Maximum sink current: 50 mA (Note) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less [at 50 mA (Note) sink current] (Note) 25 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. | Selectable either Light-ON or Dark-ON, with jog switch | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch | Incorporated | - | Yellow LED (lights up when either output 1 or output 2 is selected) | RUN: Green LED TEACH, L/D, TIMER, CUST, PRO: Yellow LED | 4 digit (green) + 4 digit (red) LED display | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustment Window comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Hysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Differential mode: 8-level settings | Incorporated | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. | 0.5 to 9,999 ms | Incorporated [Up to four sets of sensor heads can be mounted close together. (Up to two sets when in H-SP mode)] | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 30 to 1,000 mm 1.181 to 39.370 in | 30 to 250 mm 1.181 to 9.843 in | 30 to 150 mm 1.181 to 5.906 in | 30 to 150 mm 1.181 to 5.906 in | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | Multi-turn adjuster | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 1 (IEC / JIS / GB) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 1 (FDA / IEC / JIS) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 40 g approx | Explanation label: 1 set (Labels are written in Japanese and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 30 to 1,000 mm 1.181 to 39.370 in | 30 to 500 mm 1.181 to 19.685 in | 30 to 300 mm 1.181 to 11.811 in | 30 to 300 mm 1.181 to 11.811 in | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | Multi-turn adjuster | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 35 g approx Gross weight: 45 g approx | LS-MR1 Lens attachment for line reflective: 1 pc. Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance) | | | | | | | | | | | | | | | | |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 30 to 1,000 mm 1.181 to 39.370 in | 30 to 500 mm 1.181 to 19.685 in | 30 to 300 mm 1.181 to 11.811 in | 30 to 300 mm 1.181 to 11.811 in | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | Multi-turn adjuster | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | | Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 40 g approx | Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | - | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 1 (IEC / JIS / GB) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 1 (FDA / IEC / JIS) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 45 g approx | Explanation label: 1 set (Labels are written in Japanese and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 0.1 to 7 m 0.328 to 22.966 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | - | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 2 (FDA / IEC / JIS) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 45 g approx | Warning label: 1 set (Labels are written in Japanese, English and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |
| | EMC Directive, RoHS Directive | LS-401(P), LS-401(P)-C2, LS-403 | 0.1 to 5 m 0.328 to 16.404 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | 0.1 to 1 m 0.328 to 3.281 ft (Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity. | Orange LED (lights up when the amplifier output is ON) | Green LED (lights up during laser emission) | - | IP40 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | Red semiconductor laser, Class 2 (IEC / JIS / GB) (Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil) | Red semiconductor laser, Class 1 (FDA / IEC / JIS) (Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil) (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50. | Enclosure: PBT (Mounting part: PEI) Lens cover: Acrylic | 0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached) (Note) Cable cannot be extended. | Net weight: 30 g approx Gross weight: 45 g approx | RF-330(Reflector): 1 pc. Explanation label: 1 set (Labels are written in Japanese and Chinese for compliance with various standards.) | | | | | | | | | | | | | | | | |