Part No.DatasheetCE Marking Directive ComplianceSensing Range HysteresisRepeatabilitySupply Voltage Current ConsumptionOutputOutput: Utilization Category Output: Output Operation Output: Short-Circuit ProtectionResponse TimeOperation Indicator Stability IndicatorDistance AdjusterProtectionPollution Degree Ambient TemperatureAmbient HumidityAmbient IlluminanceEMCVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialCableCable ExtensionWeight (Typ.)Accessory
EMC Directive, RoHS Directive
50 to 200 mm 1.969 to 7.874 in with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
10 % or less of operation distance with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
Along sensing axis: 1 mm 0.039 in or less
Perpendicular to sensing axis: 0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
PNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
-
1 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
2-turn mechanical adjuster
IP67 (IEC)
3 (Industrial environment)
-25 to 60 degrees -13 to 140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to 70 degrees -22 to 158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
EN 60947-5-2
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (peak emission wavelength: 880 nm 0.035mil, modulated)
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 85 g approx.
MS-RX-1 (Sensor mounting bracket): 1 set
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
50 to 200 mm 1.969 to 7.874 in with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
10 % or less of operation distance with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
Along sensing axis: 1 mm 0.039 in or less
Perpendicular to sensing axis: 0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
2-turn mechanical adjuster
IP67 (IEC)
3 (Industrial environment)
-25 to 60 degrees -13 to 140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to 70 degrees -22 to 158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
EN 60947-5-2
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (peak emission wavelength: 880 nm 0.035mil, modulated)
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 3 m 9.843 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 85 g approx.
MS-RX-1 (Sensor mounting bracket): 1 set
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
50 to 200 mm 1.969 to 7.874 in with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
10 % or less of operation distance with white non-glossy paper (50 x 50 mm 1.969 x 1.969 in)
Along sensing axis: 1 mm 0.039 in or less
Perpendicular to sensing axis: 0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
1 ms or less
Red LED (lights up when the output is ON)
Green LED (lights up under stable light received condition or stable dark condition)
2-turn mechanical adjuster
IP67 (IEC)
3 (Industrial environment)
-25 to 60 degrees -13 to 140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to 70 degrees -22 to 158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
EN 60947-5-2
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (peak emission wavelength: 880 nm 0.035mil, modulated)
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
MS-RX-1 (Sensor mounting bracket): 1 set
Adjusting screwdriver: 1 pc