Long Range & Wide Area Photoelectric Sensor PX-2

The advanced optical system of the PX-2 Series reduces the null zones in front of an automatic guided vehicle (AGV). The null zones on the sides are further minimized if auxiliary Sensors, which can be easily mounted with a Connector, are used.

Part Number List

Results 7
Models table for series Long Range & Wide Area Photoelectric Sensor PX-2
Part No.DatasheetCE Marking Directive ComplianceSensing Range (Out 1 and Out 2 Areas) HysteresisSupply Voltage Power ConsumptionOUT1, OUT2OUT1, OUT2: Output Operation OUT1, OUT2: Short-Circuit Protection Extraneous Light Monitor OutputExtraneous Light Monitor Output: Output OperationResponse TimeOperation Indicators: Out 1 Area Operation Indicators: Out 2 AreaSensitivity AdjusterExternal Sensitivity Adjustment FunctionSensing AreaSleep FunctionAutomatic Interference Prevention FunctionProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialCableCable ExtensionWeight (Typ.)AccessoryApplicable Main SensorConnectable UnitsSensing Range Current ConsumptionOutputOperation Indicator
EMC Directive, RoHS Directive
3 m 9.843 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Four sensing areas are selectable with dip switches.
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 0.5 m 1.640 ft long (for input and output)
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 210 g approx.
Gross weight: 390 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
EMC Directive, RoHS Directive
3 m 9.843 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
ON when modulated beam other than its own (including auxiliary sensor's) light is received
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Sensitivity adjustment is possible with an analog input.
Four sensing areas are selectable with dip switches, and eight sensing areas are selectable with external inputs.
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 220 g approx.
Gross weight: 400 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc., Matrix chart for sensing areas and external inputs: 1 sheet
EMC Directive, RoHS Directive
1 m 3.281 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Four sensing areas are selectable with dip switches.
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 210 g approx.
Gross weight: 390 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc., Matrix chart for sensing areas and external inputs: 1 sheet
EMC Directive, RoHS Directive
5 m 16.404 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Fixed
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 210 g approx.
Gross weight: 390 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
EMC Directive, RoHS Directive
1 m 3.281 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Four sensing areas are selectable with dip switches.
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
0.3 mm2 5-core cabtyre cable, 0.5 m 1.640 ft long (for input and output)
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 210 g approx.
Gross weight: 390 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
EMC Directive, RoHS Directive
3 m 9.843 ft
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
15 % or less of operation distance
(Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.)
10 to 31 V DC including ripple
Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor)
(Note:Obtain the current consumption by the following calculation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
* OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas)
OUT2(OR circuit among the effective center, left and right OUT 2 areas)
Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.)
Incorporated
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V)
・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
ON when modulated beam other than its own (including auxiliary sensor's) light is received
80 ms or less
Red LED (lights up when the beam is received in the effective OUT 1 areas)
Yellow LED (lights up when the beam is received in the effective OUT 2 areas)
Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.)
Sensitivity adjustment is possible with an analog input.
Four sensing areas are selectable with dip switches.
Operating / sleep selectable with external input
Optical interference from up to 25 units is prevented.
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate
For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long
Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable.
Net weight: 210 g approx.
Gross weight: 390 g approx.
MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
EMC Directive, RoHS Directive
Supplied from the main sensor
Continuously variable adjuster
IP65 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Polycarbonate
0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
Net weight: 130 g approx., Gross weight: 240 g approx
MS-NX5-1 (Auxiliary sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.
PX-24, PX-24ES, PX-23ES or PX-26
Up to two PX-SB1's can be connected to one main sensor.
700 mm 27.559 in
(Note:The sensing range is specified for white non-glossy paper (300 × 300 mm 11.811 × 11.811 in) as the object.)
Current consumption of the main sensor increases by 30 mA approx. per auxiliary sensor.
OR circuit with the main sensor's OUT 1
Red LED (lights up when the beam is received)