| | EMC Directive, RoHS Directive | 3 m 9.843 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | ON when modulated beam other than its own (including auxiliary sensor's) light is received | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | Sensitivity adjustment is possible with an analog input. | Four sensing areas are selectable with dip switches, and eight sensing areas are selectable with external inputs. | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 220 g approx. Gross weight: 400 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc., Matrix chart for sensing areas and external inputs: 1 sheet | | | | | | |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | | | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | | Four sensing areas are selectable with dip switches. | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 0.5 m 1.640 ft long (for input and output) | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 210 g approx. Gross weight: 390 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. | | | | | | |
| | EMC Directive, RoHS Directive | 1 m 3.281 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | | | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | | Four sensing areas are selectable with dip switches. | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 210 g approx. Gross weight: 390 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc., Matrix chart for sensing areas and external inputs: 1 sheet | | | | | | |
| | EMC Directive, RoHS Directive | 1 m 3.281 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | | | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | | Four sensing areas are selectable with dip switches. | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | 0.3 mm2 5-core cabtyre cable, 0.5 m 1.640 ft long (for input and output) | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 210 g approx. Gross weight: 390 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. | | | | | | |
| | EMC Directive, RoHS Directive | 5 m 16.404 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | | | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | | Fixed | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 210 g approx. Gross weight: 390 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. | | | | | | |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 15 % or less of operation distance (Note:The sensing range is specified for white non-glossy paper (300 x 300 mm 11.811 × 11.811 in) as the object.) | 10 to 31 V DC including ripple | Under operation: 1.5 W or less, Under sleep condition: 0.3 W or less (without auxiliary sensor) (Note:Obtain the current consumption by the following calculation. Current consumption = Power consumption ÷ Supply voltage (e.g.) When the supply voltage is 12 V, the current consumption (operating condition) is: 1.5 W ÷ 12 V = 0.125 A = 125 mA) | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less between OUT 1 / OUT 2 and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) * OUT1(OR circuit among the effective center, left, right, adjacent left / right OUT 1 areas and the effective auxiliary left / right areas) OUT2(OR circuit among the effective center, left and right OUT 2 areas) | Selectable either Light-ON or Dark-ON with a switch (Output operation of OUT 1 and OUT 2 is the same.) | Incorporated | NPN open-collector transistor ・Maximum sink current: 100 mA ・Applied voltage: 40 V DC or less (between extraneous light monitor output and 0 V) ・Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | ON when modulated beam other than its own (including auxiliary sensor's) light is received | 80 ms or less | Red LED (lights up when the beam is received in the effective OUT 1 areas) | Yellow LED (lights up when the beam is received in the effective OUT 2 areas) | Continuously variable adjusters (OUT 1, adjacent right OUT 1, adjacent left OUT 1 and OUT 2 areas are adjusted independently.) | Sensitivity adjustment is possible with an analog input. | Four sensing areas are selectable with dip switches. | Operating / sleep selectable with external input | Optical interference from up to 25 units is prevented. | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Enclosure: ABS, Lens: Acrylic, Cover: Polycarbonate | For input and output: 0.18 mm2 9-core (PX-24ES and PX-23ES: 12-core) cabtyre cable, 0.5 m 1.640 ft long
For auxiliary sensor connection: 0.18 mm2 10-core connector attached cabtyre cable, 0.5 m 1.640 ft long10-core connector attached cabtyre cable, 0.5 m 1.640 ft long | Extension up to total 100 m 328.084 ft (10 m 32.808 ft for auxiliary sensor connection) is possible with 0.3 mm2, or more, cable. | Net weight: 210 g approx. Gross weight: 390 g approx. | MS-PX-2 (Main sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. | | | | | | |
| | EMC Directive, RoHS Directive | | | Supplied from the main sensor | | | | | | | | | | Continuously variable adjuster | | | | | IP65 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated) | Polycarbonate | 0.3 mm2 5-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. | Net weight: 130 g approx., Gross weight: 240 g approx | MS-NX5-1 (Auxiliary sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc. | PX-24, PX-24ES, PX-23ES or PX-26 | Up to two PX-SB1's can be connected to one main sensor. | 700 mm 27.559 in (Note:The sensing range is specified for white non-glossy paper (300 × 300 mm 11.811 × 11.811 in) as the object.) | Current consumption of the main sensor increases by 30 mA approx. per auxiliary sensor. | OR circuit with the main sensor's OUT 1 | Red LED (lights up when the beam is received) |