Item | Performance characteristics |
---|---|
Operation Indicator | Orange LED (lights up when output 1 and output 2 are ON) |
Laser Emission Indicator | Green LED (lights up during laser emission) |
Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: -10 to +50 ℃ +14 to +122 ℉ , if 8 to 16 units are mounted close together: -10 to +45 ℃ +14 to +113 ℉ ) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Heat-resistant ABS Transparent cover: Polycarbonate Push button switch: Acrylic Jog switch: ABS |
Cable | - (Note) The cable is not supplied as an accessory. Be sure to use the optional quick-connection cables given below. Main cable (4-core): CN-74-C1 (cable length 1 m 3.281 ft), CN-74-C2 (cable length 2 m 6.562 ft), CN-74-C5 (cable length 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length 1 m 3.281 ft), CN-72-C2 (cable length 2 m 6.562 ft), CN-72-C5 (cable length 5 m 16.404 ft) |
Weight (Typ.) | Net weight: 15 g approx Gross weight: 20 g approx |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) |
Outputs (Output 1, Output 2) | NPN open-collector transistor - Maximum sink current: 50 mA (Note) - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less [at 50 mA (Note) sink current] (Note) 25 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. |
Outputs (Output 1, Output 2): Output Operation | Selectable either Light-ON or Dark-ON, with jog switch |
Response Time | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch |
Outputs (Output 1, Output 2): Short-Circuit Protection | Incorporated |
External Input (Laser Emission Halt Full-Auto Teaching/Limit Teaching) | - |
Select Indicator | Yellow LED (lights up when either output 1 or output 2 is selected) |
Mode Indicator | RUN: Green LED TEACH, L/D, TIMER, CUST, PRO: Yellow LED |
Digital Display | 4 digit (green) + 4 digit (red) LED display |
Sensitivity Setting | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustment Window comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Hysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustment Differential mode: 8-level settings |
Fine Sensitivity Adjustment Function | Incorporated |
Timer Function | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. |
Timer Function: Time | 0.5 to 9,999 ms |
Automatic Interference Prevention Function | Incorporated [Up to four sets of sensor heads can be mounted close together. (Up to two sets when in H-SP mode)] |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |