Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Sensing Range | 5 m 16.404 ft |
Sensing Object | dia. 10 mm dia. 0.394 in or more opaque object |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | Emitter: 20 mA or less Receiver: 25 mA or less |
Sensing Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
Sensing Output: Output Operation | Switchable either Light-ON or Dark-ON |
Sensing Output: Short-Circuit Protection | Incorporated |
Self-Diagnosis Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
Self-Diagnosis Output: Output Operation | ON under unstable sensing condition |
Self-Diagnosis Output: Short-Circuit Protection | - |
Response Time | 1 ms or less |
Test Input (Emission Halt) Function | Incorporated |
Stability Indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Operation Indicator | Red LED (lights up when the sensing output is ON) |
Emitting Indicator | Red LED (lights up during beam emission) |
Sensitivity Adjuster | Continuously variable adjuster |
Protection | IP67 (IEC), IP67g (JEM) |
Ambient Temperature | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: Die-cast zinc alloy (Fluorine resin coating) Indicator cover: Polyethersulphone Lens: Polyalylate, Protective tube sheath: Oil resistant PVC |
Cable | 0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable |
Cable Extension | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. |
Weight (Typ.) | Emitter: 265 g approx Receiver: 265 g approx |
Accessory | MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc |
Repeatability (Perpendicular to Sensing Axis) | 0.5 mm 0.020 in or less |
Emitting Element | Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) |
Protective Tube Length | 2 m 6.562 ft |