| | 1NC + 1NC | 2NC | 1NO | 5m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 600 g |
| | 1NC + 1NC | 2NC | 1NC | 1m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 220 g |
| | 1NC + 1NC | 2NC | 1NO | 1m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 220 g |
| | 1NC + 1NC | 2NC | 1NO | 5m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 600 g |
| | 1NC + 1NC | 2NC | 1NC | 1m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 220 g |
| | 1NC + 1NC | 2NC | 1NC | 5m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 600 g |
| | 1NC + 1NC | 2NC | 1NC | 5m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 600 g |
| | 1NC + 1NC | 2NC | 1NO | 1m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-19, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 300 V (Door monitor circuit) 150 V (Main, Lock monitor circuit) 30 V (Between ground and LED, solenoid circuit) | 2.5 kV (Door monitor circuit) 1.5 kV (Main, Lock monitor circuit) 0.5 kV (Between ground and LED, solenoid circuit) | ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉ 2.5 A (up to 2 circuits) 1.0 A (3 or more circuits) ・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉ 1.0 A (1 circuit) 0.5 A (2 or more circuits) |
|
Ue |
|
30V |
125V |
250V |
Ie |
Main circuit, look monitor circuit |
AC |
Resistive load (AC-12) |
- |
2A |
- |
Inductive load (AC-15) |
- |
1A |
- |
DC |
Resistive load (DC-12) |
2A |
0.4A |
- |
Inductive load (DC-13) |
1A |
0.22A |
- |
Door monitor circuit |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140)(Note), 回(double insulated) (Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. | 900 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-19) | 100,000 operations min. (900 operations/hour, AC-12 125 V 2A, DC-12 125 V 0.4 A) 1,000,000 operations min. (900 operations/hour, 24 V AC/DC 0.1 A resistive load) | 500 N min. (GS-ET-19) (Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | IP 67 (IEC 60529) | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | Use 250 V / 10 A fast acting type fuse | Enclosure : PA66 | UL style 2464, No.22 AWG 12-core | DC 24 V 100% duty cycle | 110 mA (solenoid 100 mA, LED 10 mA : initial value) | Rated voltage × 85 % max. (at 20 ℃ 68 ℉) | Rated voltage × 10 % min. (at 20 ℃ 68 ℉) | Green LED | Approx. 220 g |