| | 2NC | 1 m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 120 g |
| | 2NC | 5 m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 420 g |
| | 2NC+1NO | 1 m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 120 g |
| | 3NC | 1 m 3.281 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 120 g |
| | 2NC+1NO | 5 m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 420 g |
| | 3NC | 5 m 16.404 ft | EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 | IEC 60204-1, EN 60204-1 | Machinery directive (2006/42/EC) Low voltage directive (2006/95/EC) | -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage : -40 to +80 ℃ -40 to +176 ℉ | 45 to 85 % RH | 3 (Inside 2) | 2,000 m 6,561.68 ft max. | 4 kV | 300 V | 2.5 A |
|
Ue |
|
30V |
125V |
250V |
Ie |
AC |
Resistive load (AC-12) |
- |
2.5A |
1.5A |
Inductive load (AC-15) |
- |
1.5A |
0.75A |
DC |
Resistive load (DC-12) |
2.5A |
1.1A |
0.55A |
Inductive load (DC-13) |
2.3A |
0.55A |
0.27A |
| Class II (IEC 61140), 回(double insulated) | IP 67 (IEC 60529) | Malfunction : 300 m/s2 Destruction : 1,000 m/s2 | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in | 1,200 operations/hour | 0.05 to 1.0 m/sec. | 2,000,000 (ISO 13849-1 Annex C Table C.1) | 1,000,000 operations min. (GS-ET-15) | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) | 8 mm 0.315 in min. | 60 N min. | 300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) | Use 250 V / 10 A fast acting type fuse | 50 A (250 V) | Enclosure : PA66 | UL style 2464, No.20 AWG 6-core | Approx. 420 g |