| | Machinery Directive, EMC Directive, RoHS Directive | | | | | | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 1), Galden (Note 1), Hydrofl uoric acid etc. (Note 2) (Note 1:The agents mentioned above are examples. It may not be detected depending on viscosity the agent.Before using this device, check the detecting liquid and installation condition.) (Note 2:Fluorinert is the world wide trademark of 3M. Galden is the registered trademark of Solvay.) | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 1), Galden (Note 1), Hydrofl uoric acid etc. (Note 2) (Note 1) Fluorinert(TM) is the world wide trademark of 3M. Galden is the world wide trademark of Solvay Solexis. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 30 mA or less | DC-12, DC-13 | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | 10 ms or less | ON when normal condition or initial detection, OFF when detection leakage or wrong installation | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection auxiliary output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | 50 ms or less | ON when normal condition, OFF when initial detection or accidental leakage | | | | | | | | IP65 / IP67 (IEC) | | | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉ (Note) Liquid being detected should be also kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Infrared LED (modulated) | | | Enclosure: PFA | 0.1 mm2 4-core PFA cabtyre cable, 2 m 6.562 ft long | Net weight: 45 g approx Gross weight: 110 g approx |
| | Machinery Directive, EMC Directive, RoHS Directive | | | | | | Water (Standard liquid) (Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | Water (Standard liquid) (Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 30 mA or less | DC-12, DC-13 | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) | 10 ms or less | ON when normal condition or initial detection, OFF when detection leakage or wrong installation | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection auxiliary output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) | 50 ms or less | ON when normal condition, OFF when initial detection or accidental leakage | | | | | | | | IP65 / IP67 (IEC) | | | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉ (Note) Liquid being detected should be also kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Infrared LED (modulated) | | | Enclosure: Polypropylene | 0.18 mm2 4-core PVC cabtyre cable, 2 m 6.562 ft long | Net weight: 45 g approx Gross weight: 110 g approx |
| | Machinery Directive, EMC Directive, RoHS Directive | | | | | | Water (Standard liquid) (Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | Water (Standard liquid) (Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 30 mA or less | DC-12, DC-13 | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | 10 ms or less | ON when normal condition or initial detection, OFF when detection leakage or wrong installation | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: Same as the supply voltage (between detection auxiliary output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current) | 50 ms or less | ON when normal condition, OFF when initial detection or accidental leakage | | | | | | | | IP65 / IP67 (IEC) | | | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉ (Note) Liquid being detected should be also kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Infrared LED (modulated) | | | Enclosure: Polypropylene | 0.18 mm2 4-core PVC cabtyre cable, 2 m 6.562 ft long | Net weight: 45 g approx Gross weight: 110 g approx |
| | Machinery Directive, EMC Directive, RoHS Directive | | | | | | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 1), Galden (Note 1), Hydrofl uoric acid etc. (Note 2) (Note 1:The agents mentioned above are examples. It may not be detected depending on viscosity the agent.Before using this device, check the detecting liquid and installation condition.) (Note 2:Fluorinert is the world wide trademark of 3M. Galden is the registered trademark of Solvay.) | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 1), Galden (Note 1), Hydrofl uoric acid etc. (Note 2) (Note 1) Fluorinert(TM) is the world wide trademark of 3M. Galden is the world wide trademark of Solvay Solexis. (Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 30 mA or less | DC-12, DC-13 | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) | 10 ms or less | ON when normal condition or initial detection, OFF when detection leakage or wrong installation | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: Same as the supply voltage (between detection auxiliary output and +V) - Residual voltage: 2.5 V or less (at 50 mA source current) | 50 ms or less | ON when normal condition, OFF when initial detection or accidental leakage | | | | | | | | IP65 / IP67 (IEC) | | | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉ (Note) Liquid being detected should be also kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Infrared LED (modulated) | | | Enclosure: PFA | 0.1 mm2 4-core PFA cabtyre cable, 2 m 6.562 ft long | Net weight: 45 g approx Gross weight: 110 g approx |
| | Machinery Directive, EMC Directive, RoHS Directive | ISO 13849-1 (Category 4, PLe), IEC 60947-5-2, IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3) | JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) | EN 60947-5-2, EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3) (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. | S1-G-1-2009, S2-W-5-2009 | Conforming to SEMI-S2-0310a | | | 24 V DC+10-15 % Ripple P-P 10 % or less | 200 mA or less | | | | | | | | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 200 mA - Applied voltage: Same as power voltage (between control output to +V) - Residual voltage: 2.5 V or less (at 200 mA source current) [Selecting NPN output] - Maximum sink current: 200 mA - Applied voltage: Same as power voltage (between control output to 0 V) - Residual voltage: 2.0 V or less (at 200 mA sink current) | ON when normal condition or initial detection, OFF when detection leakage or wrong installation | 20 ms or less (excluding the response time of the sensor) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 60 mA - Applied voltage: Same as power voltage(between sensor monitor output to +V) - Residual voltage: 2.5 V or less (at 60 mA source current) [Selecting NPN output] - Maximum sink current: 60 m A - Applied voltage: Same as power voltage(between sensor monitor output to 0 V) - Residual voltage: 2.0 V or less (at 60 mA sink current) | ON when normal condition, OFF when initial detection or accidental leakage | 100 ms or less (excluding the response time of the sensor) | OFF for lockout (Rating: Same as sensor monitor output) | IP20 (IEC) (However, it should be in IP54 protection structure of control panel) | Interlock / lockout cancel / Test input / External device monitor / Safety input / Control output polarity selection / Non-safety output polarity selection / Sensor connection number setting | Negative logic output of control output 1 / 2 (OSSD 1 / 2) (Rating: Same as sensor monitor output) [Auxiliary output ON when control output 1 / 2 (OSSD 1/2) is OFF] | -10 to +55 ℃ +14 to +131℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | | 2.55 x 10-9 (when connecting 4 safety liquid connecting sensors) | 100 years or more | Main unit case: PC + ABS (alloy) | | Net weight: 170 g approx Gross weight: 440 g approx |