| | EMC Directive, RoHS Directive | 1.5 sec. approx.(±1,000 V → ±100 V) (Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | ±10 V or less (Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | 24 V DC ±10% | 400 mA or less | High-frequency AC method | ± 2 kV approx. | Error output, Discharge halt input | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | 0.04 ppm or less (Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed), Storage : -10℃ to +65℃ +14℉ to +149℉ | 35% RH to 65% RH (No dew condensation allowed), Storage : 35% RH to 65% RH | C (capacitor) grounding | Enclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC | New weight : 790 g approx. | Straight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc. (Note): The discharge needle unit is loaded on the straight louver before shipment. | If not specified, the ambient temperature for measurement is +20℃ +68℉. |
| | EMC Directive, RoHS Directive | 1 sec. approx.(±1,000 V → ±100 V) (Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | ±10 V or less (Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | 24 V DC ±10% | 700 mA or less | High-frequency AC method | ± 2 kV approx. | Error output, Discharge halt input | Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green) | 0.04 ppm or less (Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed. | 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed), Storage : -10℃ to +65℃ +14℉ to +149℉ | 35% RH to 65% RH (No dew condensation allowed), Storage : 35% RH to 65% RH | C (capacitor) grounding | Enclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC | New weight : 790 g approx. | Straight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc. (Note): The discharge needle unit is loaded on the straight louver before shipment. | If not specified, the ambient temperature for measurement is +20℃ +68℉. |