| | EMC Directive, RoHS Directive | 1 sec. or less (plus or minus1,000 V to plus or minus100 V) (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) | plus or minus10 V or less (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) | 0.03 ppm or less (Note) A typical sample applied with a power voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. | Air (dried clean air) (Note) The air is dried (dew point: equivalent of –20 ℃ – 4 ℉) and filtered (mesh-size: equivalent of 0.01 microm 0.0004 mil) air. | 500 liter/min. (ANR) or less (Note) The applicable pressure range depends on the nozzle to be used. | 0.05 to 0.7 MPa (Note) The applicable pressure range depends on the nozzle to be used. | 24 V DC plus or minus10 % | 70 mA or less | High frequency AC method | 2,000 V approx. | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between check output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) | ON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal (Note) When confirming the check output, carry out discharge for 2 sec. or more. | Incorporated | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between error output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) | OFF when abnormal discharge is detected, ON when operation is normal | Incorporated | Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)
(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) | When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting the power supply’s 0 V line. | Green LED (lights up when the power is ON) | Green LED (lights up when discharging)
(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) | Orange LED (lights up when the discharge needle is worn or dirty, etc.) (Note) When confirming the check output, carry out discharge for 2 sec. or more. | Red LED (lights up when abnormal discharge is detected) | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed) | 35 to 65 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | Cable with a connector, 0.5 m 1.640 ft long | Enclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten | Net weight: 120 g approx. | Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)] |