EP Series DC Contactors are high-voltage, high-current control capable offering a high capacity of maximum 1,000 Volt DC cutoff. These DC Contactors are compact and generate little operating sound, even when large currents are cut off. EP Series parts are highly reliable because they are hermetically sealed with H2 mixed gas that provides stability regardless of ambient conditions. They can be mounted in any direction. Panasonic offers a wide selection of EP Series models including PC Board Type (10A), TM Type (10A and 20A), Lead Wire Type (200A) and Connector Type (80A and 300A). The 10A, 20A and 80A Types are UL/C-UL standard certified and RoHS Compliant.
Features:
High Voltage/High Current Control Capable
High Contact Reliability
Magnetic Arc Suppression
Compact Size
Low Operating Sound
Benefits:
Stable Contact Resistance, Even Under High Load
Longer Lifetime in a Smaller Package
Safe Operation
Smaller Size Provides Flexible Installation
Quiet Operation
EP Series Relays
Part number list
Results 16
Models table for series EP Series Relays
Part No.
Datasheet
Contact Capacity
Coil Voltage
Rated operating power
Terminal Type
Contact Arrangement
Nominal Switching Capacity (Resistive Load)
Max. Switching Voltage
Minimum (For Reference)
Accessories
Pick-Up Voltage
Drop-Out Voltage
Expected Life: Mechanical
Expected Life: Electrical
Breakdown Voltage (Contact-Contact) (Initial)
Breakdown Voltage (Initial) : Between Contact And Coil
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 4.17% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
10 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min)(Resistive load) 20 A 400 V DC Min. 3x103ope. (switching frequency: 6 times/min)(Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 8.3% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
60 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min) (Resistive load) 200 A 400 V DC Min. 3x103ope. (switching frequency: 20 times/min) (Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 8.3% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
60 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min) (Resistive load) 200 A 400 V DC Min. 3x103ope. (switching frequency: 20 times/min) (Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 4.17% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
10 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min)(Resistive load) 20 A 400 V DC Min. 3x103ope. (switching frequency: 6 times/min)(Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 8.3% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
60 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min) (Resistive load) 200 A 400 V DC Min. 3x103ope. (switching frequency: 20 times/min) (Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)
Max. 75% V of rated coil voltage (initial) (at 20°C)
Min. 8.3% V of rated coil voltage (initial) (at 20°C)
Min. 200x103 ope.
60 A 1,000 V DC Min. 103ope. (switching frequency: 6 times/min) (Resistive load) 200 A 400 V DC Min. 3x103ope. (switching frequency: 20 times/min) (Resistive load)
2500Vrms
2500Vrms
Ambient temperature: -40° to +80°C (storage: Max. +85°C) Humidity: 5 to 85% RH (Avoid icing and condensation)