Specifications

Specifications table for model ADZS12124
ItemPerformance characteristics
Operating Function 1 coil latching
Rated Coil Voltage24 V DC
Protective ConstructionDust Cover
Terminal TypeVertical terminal
Contact TypeHigh switching capacity
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)200
Set Voltage Max. 70% V of rated coil voltage (Initial)
Reset VoltageMax. 70% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)62.5 mA
Resistance [±10%] (at 20°C) 384 Ω
Rated Operating Power 1.5 W
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact Arrangement1 Form A
Contact ShapeSingle
Contact Resistance (Initial)Max. 1 mΩ (at 90 A), Max. 5 mΩ (at 10 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)90 A 250 V AC
Max. Switching Power (Resistive Load) 24,840 VA
Max. Switching Voltage276 V AC
Max. Switching Current90 A (AC)
Min. Switching Load (Reference Value) 100 mA 125 V AC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts2,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil12,000 V
Time (Initial) (at 20°C 68°F) (Initial) Max. 20 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 20 ms at rated coil voltage (without bounce)
Hock Resistance (Functional)300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2 mm)
Mechanical LifeMin. 100x103 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +85℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 45 g
Resistive Load[switching frequency: at 20 times/min (ON : OFF = 2 s : 4 s)]
Min. 10x103 ope. 90 A 250 V AC
UC3 Class (IEC62055-31)[switching frequency ON : OFF = 10 s : 20 s]
Min. 10x103 ope. 90 A 276 V AC
(cosΦ = 1 : 5,000 cycles, cosΦ = 0.5 : 5,000 cycles)
Contact Voltage Drop (Initial)Max. 0.09 V (at 90 A), Max. 0.05 V (at 10 A)

Stock check

Model image for ADZS12124

ADZS12124

Latest Videos

Playlist

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for NPI: SF-M Series Relays

NPI: SF-M Series Relays

Thumbnail for SF-M Series Safety Relays

SF-M Series Safety Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap