Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
Tube
25
1,000
Models table for series TA Series Relays
Part No.
Datasheet
Rated Coil Voltage
Coil Resistance (at 20oC)
Contact Arrangement
Protective Construction
Terminal Type
Operating Function
Operate (Set) Voltage (at20°C) (Initial)
Release (Reset) voltage (at20℃) (Initial)
Rated Operating Current [±10%] (at 20°C)
Coil Resistance (At 20oC)
Rated Operating Power
Usable Voltage Range
Contact Type
Contact Resistance (Initial)
Contact Material
Nominal Switching Capacity (Resistive Load)
Contact Data: Max. Carrying Current
Min. Switching Load (Resistive)
Insulation Resistance (Min. MΩ)(Initial)
Dielectric Strength (Between Open Contacts) (Initial)
Dielectric Strength (Between Contacts and Coil) (Initial)
Operate (Set) Time (At Rated Coil Voltage) (At 20oC) (Initial)
Release (Reset) Time (at Rated Coil Voltage) (at 20°C) (Initial)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation)