Panasonic’s HE Series Relays are characterized by their coil holding voltage, which can be reduced up to 30% V of the nominal coil voltage. This results in an operating power of approximately 170 mW, which contributes to equipment energy savings. The HE Series Relays are ideal for various applications such as photovoltaic power generation systems, uninterruptible power supplies, industrial equipment, and more.

Features:

  • High Capacity and Long Life: 35A 277V AC 5×104
  • Compact Size and Low Operating Power
  • Insulation Distance
  • Mirror Contact Mechanisms
  • RoHS Compliant

Part Number List

Results 72
Models table for series HE Series Relays
Part No.DatasheetTerminal TypeCoil TypeRated Coil VoltageRated Operating Power Contact ArrangementProtective ConstructionOperating Function AccessoriesPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Max. Allowable Voltage Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Mechanical LifeVibration Resistance (Functional) Vibration Resistance (Destructive)ConditionsWeight (Typ.)Resistive LoadPacking QuantityInsulation DistanceContact Gap
Plug-in terminal
DC type (DC coil)
6 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
320 mA
18.8 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Plug-in terminal
DC type (DC coil)
12 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
160 mA
75 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Plug-in terminal
DC type (DC coil)
24 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
80 mA
300 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Plug-in terminal
DC type (DC coil)
48 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
1,200 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Plug-in terminal
DC type (DC coil)
100 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
19 mA
5,200 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Plug-in terminal
AC type (AC coil)
12 V AC
1.7 VA
1 Form A
Dust Cover
Single side stable
Terminals are available.
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 15% V of rated coil voltage (Initial)
138 mA
110% V of rated coil voltage (at 20°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 30 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 5x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Screw terminal
DC type (DC coil)
48 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
10
50
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
1,200 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 120 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Screw terminal
DC type (DC coil)
110 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
10
50
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
18 mA
6,300 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 120 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Tab terminal (TM type)
DC type (DC coil)
48 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
1,200 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)
Tab terminal (TM type)
DC type (DC coil)
100 V DC
1,920 mW
1 Form A
Dust Cover
Single side stable
20
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
19 mA
5,200 Ω
110% V of rated coil voltage (at 55°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
30 A 277 V AC
8,310 VA
277 V AC, 30 V DC
30 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 30 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
Min. 10x106 ope. (switching frequency: at 180 times/min)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Ambient temperature: -50 to +55°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 90 g
[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Carton
Min. 8 mm
Min. 3 mm (reference value)