Specifications
Item | Performance characteristics |
---|---|
Rated Coil Voltage | 12V DC |
Contact Arrangement | 1 Form A |
Terminal Type | Screw terminal |
Coil Terminal Structure | Lead wire |
Terminal Structure | Cu without plating, with hole |
Operating Function | Single side stable |
Operate (Set) Voltage (at20°C) (Initial) | Max. 9 V DC |
Release (Reset) voltage (at20°C) (Initial) | Min. 0.5V DC |
Rated Operating Current [±10%] (at 20°C) | 0.167 A |
Coil Resistance (At 20oC) | 72Ω |
Rated Operating Power (at 20°C) | 2.0 W |
Max. applied voltage | 16 V DC |
Contact Material | Ag alloy |
Nominal Switching Capacity (Resistive Load) | 100A 60V DC (Carry, 38 mm2 wire) |
Max. Carring Current | 100 A continuous / 300 A 5 sec. (38 mm2 wire) (Carry only) |
Min. Switching Load (Resistive) | 1A 24 V DC (at 20°C) |
Contact Voltage Drop (Initial) | Max. 0.02 V (by voltage drop 6 V DC 20 A) |
Insulation Resistance (Min. MΩ)(Initial) | Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Between Open Contacts) (Initial) | 1,500 V AC for 1min. (detection current: 10 mA) |
Dielectric Strength (Between Contacts and Coil) (Initial) | 2,000 V AC for 1min. (detection current: 10 mA) |
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial) | Max. 50ms (without bounce) |
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20°C) (Initial) | Max. 30 ms (with no coil protective elements) |
Shock Resistance: Functional | For ON: Min. 490 m/s2 (half-sine shock plus: 11 ms; detection time: 10µs) For OFF: Min. 147 m/s2 (half-sine shock pulse: 11 ms; detection time: 10µs) |
Shock Resistance: Destructive | Min. 490 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance: Functional | 10 to 200 Hz, 44.1m/s2 (detection time: 10 µs) |
Vibration Resistance: Destructive | 10 to 200 Hz, 44.1m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours) |
Expected Life: Mechanical Life | Min. 400,000 operations (Swiching frequency: 0.5 s ON, 1 s OFF) |
Expected Life: Electrical Life (Resistive) | 2 A 60 V DC Min. 50,000 operations (Switching frequency: 5 s ON, 5 s OFF) |
Expected Life: Switch-Off Life | [Forward direction] 1,500 A 60 V DC, Min. 1 operation [Reverse direction] 500 A 60 V DC, Min. 1 operation |
Expected Life: Inrush Resistance Current<br>(Capacitor; 2000µF) | 150 A 6 V DC, Min. 100,000 operations Switching frequency: 1 s ON, 2 s OFF |
Conditions | Ambient temperature: –40 to +85°C, Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) |
Weight (Typ.) | Approx. 140 g |
Inner Carton (Pieces) | 50 pieces / 1 tray |
Outer Carton (Pieces) | 50 |
Usable Voltage Range | 10 V DC to 16 V DC |
Stock check
AEBN11112