Specification

Specifications table for model ACNL111
ItemPerformance characteristics
Mounting Type Screw mounting
Rated Coil Voltage12V DC
Contact Arrangement1 Form A
Contact Capacity150A
Protective ConstructionSealed
Terminal TypeScrew terminal
Operating Function Latching
Operate (Set) Voltage (at 20°C 68°F) (Initial)Max. 7.0V DC
Release (Reset) voltage (at 20°C) (Initial)Max. 7.0V DC
Rated Operating Current [±10%] (at 20°C)2.5A
Coil Resistance (At 20oC)4.8Ω
Rated Operating Power (at 20°C) 30 W
Max. applied voltage16V DC
Contact Resistance (Initial)Max. 1.5mΩ (typ. 0.4mΩ) (By voltage drop 6 V DC 1 A)
Max. 1.0mΩ (By voltage drop 6 V DC 10 A)
Contact MaterialAg alloy
Nominal Switching Capacity (Resistive Load) 150A 14V DC
Continuous Carrying Current150 A (at 85°C 185°F, Connection cable: 38 mm2)
80 A (at 125°C 257°F, Connection cable: 38 mm2)
Contact Data: Max. Carrying Current1,500 A for 0.5 seconds ([at forward direction] at 20°C 68°F, Connection cable: 38 mm2)
Max. Cut-Off Current350 A 14 V DC
(1,000 times or more in forward direction, Switching frequency: 1s ON, 9s OFF, at 20°C 68°F, Connection cable: 38 mm2)
Min. Switching Load (Resistive) 1A 14V DC (at 20°C 68°F)
Contact Voltage Drop (Initial)Max. 0.1 V (at 100 A, 12 V DC)
Insulation Resistance (Min. MΩ)(Initial)Min. 10 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Dielectric Strength (Between Open Contacts) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Dielectric Strength (Between Contacts and Coil) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 10ms (without contact bounce time)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 10ms (Without contact bounce time) (Without diode)
Shock Resistance: Functional Min. 250 m/s2 (N.O. side: closing)
Min. 500 m/s2 (N.O. side: open, set/reset reversal)
(Half-wave pulse of sine wave: 11ms; detection time: 10μs)
Shock Resistance: DestructiveMin. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms)
Vibration Resistance: Functional10 Hz to 500 Hz, Min. 44.1m/s2 (Detection time: 10μs)
Vibration Resistance: Destructive10 Hz to 500 Hz, Min. 44.1m/s2
(Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 3x105 (Switching frequency: 30 times/min.)
Expected Life: Electrical150 A 14 V DC resistive load, Min. 3x104
(Switching frequency: 1s ON, 9s OFF, at 85°C 185°F, Connection cable: 38 mm2)
ConditionsAmbient temperature: –40°C to +125°C –40°F to +257°F,
Humidity: 2% R.H. to 85% R.H. (Please avoid icing or condensation)
Weight (Typ.)Approx. 150 g 5.29 oz
Outer Carton (Pieces) 25

Stock Check

What's New

Stay up to date