Specifications

Specifications table for model CA1bS-12V-N-5
ItemPerformance characteristics
Protective ConstructionSealed
Mounting Type Screw mounting type
Protective ElementNone
Rated Coil Voltage12V DC
Rated Operating Power Low operating power type (1.4 W)
Contact Arrangement1 Form B
Terminal TypePlug-in type
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 8V DC
Release (Reset) voltage (at20℃) (Initial)0.6 to 6V DC
Rated Operating Current [±10%] (at 20°C)120 mA
Coil Resistance (At 20oC)100Ω
Usable Voltage Range10 to 16V DC
Contact Resistance (Initial)Max. 50mΩ (typ. 3mΩ) (By voltage drop 1A 6V DC)
Contact MaterialAg alloy
Nominal Switching Capacity (Resistive Load) 20A 12V DC
Contact Data: Max. Carrying Current20A continuous (Coil applied voltage 14V DC, at 80°C 176°F)
Min. Switching Load (Resistive) 1A 14V DC (at 20°C 68°F)
Contact Voltage Drop (After Electrical Life Test)Max. 0.3 V (By carring 20 A 12V DC)
Insulation Resistance (Min. MΩ)(Initial)Min. 10 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Dielectric Strength (Between Open Contacts) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Dielectric Strength (Between Contacts and Coil) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 10ms (without contact bounce time)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 10ms (Without contact bounce time) (Without diode)
Shock Resistance: Functional Min. 100 m/s2 [approx. 10G] (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Shock Resistance: DestructiveMin. 1,000 m/s2 [approx. 100G] (Half-wave pulse of sine wave: 6ms)
Vibration Resistance: Functional33 Hz, Min. 44.1 m/s2 [approx. 4.5G] (Detection time: 10µs)
Vibration Resistance: Destructive33 Hz, Min. 44.1 m/s2 [approx. 4.5G] (Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 106 (at 120 cpm)
Expected Life: Electrical[Resistive load] Min. 105
at rated switching capacity, operating frequency: 2s ON, 2s OFF
[Motor load] Min. 105 at 12V DC, 60A (Inrush), 20A (Steady),
Operating frequency: 2s ON, 2s OFF
[Halogen lamp load] Min. 105 at 12V DC, 100A (Inrush), 20A (Steady)
Operating frequency: 1s ON, 14s OFF
ConditionsAmbient temperature: –30 to +80°C –22 to +176°F, Humidity: 5 to 85% R.H. (Please avoid icing or condensation)
Weight (Typ.)Approx. 19 g .67 oz
Water-Proof StandardJIS D0203 S2
Inner Carton (Pieces)20
Outer Carton (Pieces) 200

Stock check

Model image for CA1bS-12V-N-5

CA1bS-12V-N-5

Latest Videos

Playlist

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for Panasonic Automotive Solutions for Electrified Drivetrain

Panasonic Automotive Solutions for Electrified Drivetrain