Specifications
Item | Performance characteristics |
---|---|
Rated Coil Voltage | 12V DC |
Operate (Set) Voltage | Max. 5.5V DC |
Contact Arrangement | 1 Form A |
Protective Construction | Sealed |
Terminal Type | PC board type |
Operating Function | Single side stable |
Operate (Set) Voltage (at20°C) (Initial) | Max. 5.5V DC |
Release (Reset) voltage (at20°C) (Initial) | Min. 0.8V DC |
Rated Operating Current [±10%] (at 20°C) | 53.3 mA |
Coil Resistance (At 20oC) | 225Ω |
Rated Operating Power (at 20°C) | 640 mW |
Usable Voltage Range | 10 to 16V DC |
Contact Resistance (Initial) | Max. 30mΩ (typ. 5mΩ) (By voltage drop 1A 6V DC) |
Contact Material | Ag alloy |
Nominal Switching Capacity (Resistive Load) | 30A 14V DC |
Contact Data: Max. Carrying Current | 30A/1 hour, 40A/2 min. (Coil applied voltage 16V DC at 20°C 68°F) 25A/1 hour, 35A/2 min. (Coil applied voltage 16V DC at 85°C 185°F) 20A/1 hour, 30A/2 min. (Coil applied voltage 16V DC at 110°C 230°F) |
Min. Switching Load (Resistive) | 1A 14V DC (at 20°C 68°F) |
Insulation Resistance (Min. MΩ)(Initial) | Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.) |
Dielectric Strength (Between Open Contacts) (Initial) | 500 Vrms for 1 min. (Detection current: 10mA) |
Dielectric Strength (Between Contacts and Coil) (Initial) | 500 Vrms for 1 min. (Detection current: 10mA) |
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial) | Max. 10ms (without contact bounce time) |
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20°C) (Initial) | Max. 10ms (Without contact bounce time) (Without diode) |
Shock Resistance: Functional | Min. 100 m/s2 [approx. 10G] (Half-wave pulse of sine wave: 11ms; detection time: 10µs) |
Shock Resistance: Destructive | Min. 1,000 m/s2 [approx. 100G] (Half-wave pulse of sine wave: 6ms) |
Vibration Resistance: Functional | 10 to 100 Hz, Min. 44.1 m/s2 [approx. 4.5G] (Detection time: 10µs) |
Vibration Resistance: Destructive | 10 to 500 Hz, Min. 44.1 m/s2 [approx. 4.5G], Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours |
Expected Life: Mechanical Life | Min. 107 (at 120 cpm) |
Expected Life: Electrical | [Resistive load] Min. 105 (at rated switching capacity, operating frequency: 1s ON, 1s OFF) [Motor load] Min. 3 x 105 (motor free) (at inrush 84 A, steady 18A, 14 V DC operating frequency: ON 2s, OFF 5s) [Lamp load] Min. 2 x 105 (at inruch 84 A, steady 12A, 14 V DC operating frequency: ON 1s, OFF 14s) |
Conditions | Ambient temperature: –40 to +110°C –40 to +230°F, Humidity: 2 to 85% R.H. (Please avoid icing or condensation) |
Weight (Typ.) | Approx. 9 g .32 oz |
Packing Quantity | Tube |
Inner Carton (Pieces) | 50 |
Outer Carton (Pieces) | 1,000 |