Specifications

Specifications table for model ACT112
ItemPerformance characteristics
Rated Coil Voltage12V DC
Contact Arrangement1 Form C
Protective ConstructionSealed
Terminal TypePC board type
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 7.2V DC
Release (Reset) voltage (at20℃) (Initial)Min. 1.0V DC
Rated Operating Current [±10%] (at 20°C)66.7 mA
Coil Resistance (At 20oC)180Ω
Rated Operating Power (at 20°C) 800 mW
Usable Voltage Range10 to 16V DC
Contact Resistance (Initial)Max. 100mΩ (N.O. side: typ. 7mΩ, N.C. side: typ. 10mΩ) (By voltage drop 1A 6V DC)
Contact MaterialAg alloy
Nominal Switching Capacity (Resistive Load) N.O.side: 20A 14V DC, N.C.side: 10A 14V DC
Contact Data: Max. Carrying CurrentN.O.side:
25A for 1 hour, 35A/2 min. (Coil applied voltage 14V DC, at 20°C 68°F)
20A for 1 hour, 30A/2 min. (Coil applied voltage 14V DC, at 85°C 185°F)
Min. Switching Load (Resistive) 1A 14V DC (at 20°C 68°F)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Dielectric Strength (Between Open Contacts) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Dielectric Strength (Between Contacts and Coil) (Initial)500 Vrms for 1 min. (Detection current: 10mA)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 10ms (without contact bounce time)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 10ms (Without contact bounce time) (Without diode)
Shock Resistance: Functional Min. 100 m/s2 [approx. 10G] (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Shock Resistance: DestructiveMin. 1,000 m/s2 [approx. 100G] (Half-wave pulse of sine wave: 6ms)
Vibration Resistance: Functional10 to 100 Hz, Min. 44.1 m/s2 [approx. 4.5G] (detection time: 10µs)
Vibration Resistance: Destructive10 to 500 Hz, Min. 44.1m/s2[approx. 4.5G]
(Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 107 (at 120 cpm)
Expected Life: Electrical[Resistive load]
Min. 105 (at rated switching capacity, operating frequency: 1s ON, 9s OFF
[Motor load]
N.O. side: Min. 2x105 at Inrush 25A, Steady 5A 14V DC, Min. 105 at 25A 14V DC motor lock condition
N.C. side: Min. 2x105 at brake current 20A 14V DC (operating frequency: 0.5s ON, 9.5s OFF)
ConditionsAmbient temperature: –40 to +85°C –40 to +185°F,
Humidity: 5 to 85% R.H. (Please avoid icing or condensation)
Weight (Typ.)Approx. 4 g .14 oz
Packing QuantityTube
Inner Carton (Pieces)30
Outer Carton (Pieces) 1,500

Stock check

Model image for ACT112

ACT112

Latest Videos

Playlist

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for Panasonic Automotive Solutions for Electrified Drivetrain

Panasonic Automotive Solutions for Electrified Drivetrain