| | 12V DC | 225Ω | 1 Form C | Sealed | PC board type | Single side stable | Max. 7.7V DC | Min. 0.8V DC | 53.3 mA | 225Ω | 640 mW | 10 to 16V DC | Standard type | Max. 50mΩ (N.O. side: typ. 5mΩ, N.C. side: typ. 6mΩ) (By voltage drop 1A 6V DC) | Ag alloy | N.O. side: 20A 14V DC, N.C. side: 10A 14V DC | 25A/ 3 min (Coil applied voltage 12V DC, at 20°) | 1A 14V DC (at 20°C) | Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.) | 500 Vrms for 1 min (Detection current: 10mA) | 500 Vrms for 1 min (Detection current: 10mA) | Max. 10ms (without contact bounce time) | Max. 10ms (Without contact bounce time) (Without protective element) | Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs) | Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times) | 10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs) | 10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours | Min. 107 (at 120 times/min) | [Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF | Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 8 g | Tube | 25 | 1,000 |
| | 12V DC | 160Ω | 1 Form C | Sealed | PC board type | Single side stable | Max. 6.5V DC | Min. 0.8V DC | 75 mA | 160Ω | 900 mW | 10 to 16V DC | Standard type | Max. 50mΩ (N.O. side: typ. 5mΩ, N.C. side: typ. 6mΩ) (By voltage drop 1A 6V DC) | Ag alloy | N.O. side: 20A 14V DC, N.C. side: 10A 14V DC | 25A/ 3 min (Coil applied voltage 12V DC, at 20°) | 1A 14V DC (at 20°C) | Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.) | 500 Vrms for 1 min (Detection current: 10mA) | 500 Vrms for 1 min (Detection current: 10mA) | Max. 10ms (without contact bounce time) | Max. 10ms (Without contact bounce time) (Without protective element) | Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs) | Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times) | 10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs) | 10 to 100 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours | Min. 107 (at 120 times/min) | [Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF | Ambient temperature: –40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 8 g | Tube | 25 | 1,000 |