TJ Series Relays

Part number list

Results 1
Models table for series TJ Series Relays
Part No.DatasheetProtective ConstructionRated Coil VoltageCoil Resistance (at 20oC)Heat Resistance of TypesContact ArrangementContact TypeTerminal TypeOperating Function Operate (Set) Voltage (at20°C) (Initial) Release (Reset) voltage (at20°C) (Initial)Rated Operating Current [±10%] (at 20°C)Coil Resistance (At 20oC)Rated Operating Power Usable Voltage RangeContact Resistance (Initial)Contact MaterialNominal Switching Capacity (Resistive Load) Contact Data: Max. Carrying CurrentMin. Switching Load (Resistive) Insulation Resistance (Min. MΩ)(Initial)Dielectric Strength (Between Open Contacts) (Initial)Dielectric Strength (Between Contacts and Coil) (Initial)Operate (Set) Time
(At Rated Coil Voltage) (At 20oC) (Initial)
Release (Reset) Time
(at Rated Coil Voltage) (at 20°C) (Initial)
Shock Resistance: Functional Shock Resistance: DestructiveVibration Resistance: FunctionalVibration Resistance: DestructiveExpected Life: Mechanical LifeExpected Life: ElectricalConditionsWeight (Typ.)Packing QuantityInner Carton (Pieces)Outer Carton (Pieces)
Sealed
12V DC
320Ω
High heat-resistant type
1 Form C
Standard type
PC board type
Single side stable
Max. 7.0V DC
Min. 0.8V DC
37.5 mA
320Ω
450 mW
10 to 16V DC
Max. 50mΩ (N.O. side: typ. 2.5mΩ, N.C. side: typ. 3mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 30A 14V DC, N.C. side: 15A 14V DC
30A/ 1 hour (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2,
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 7 g
Tube
40
800
Latest Videos

Playlist

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays