| | Single side stable | 24 V DC | 2 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | Max. 70% V of rated coil voltage (Initial) | | Min. 10% V of rated coil voltage (Initial) | | 8.3 mA | 2,880 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | | | Max. 10 ms at rated coil voltage (without bounce) | 4,000 Vrms for 1 min (detection current: 10 mA) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |
| | Single side stable | 12 V DC | 2 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | Max. 70% V of rated coil voltage (Initial) | | Min. 10% V of rated coil voltage (Initial) | | 16.6 mA | 720 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | | | Max. 10 ms at rated coil voltage (without bounce) | 4,000 Vrms for 1 min (detection current: 10 mA) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |
| | 2 coil latching | 24 V DC | 2 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 8.3 mA Reset coil: 8.3 mA | Set coil: 2,880 Ω Reset coil: 2,880 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | 4,000 Vrms for 1 min (detection current: 10 mA) | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |
| | 2 coil latching | 12 V DC | 2 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 16.6 mA Reset coil: 16.6 mA | Set coil: 720 Ω Reset coil: 720 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | 4,000 Vrms for 1 min (detection current: 10 mA) | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |
| | 2 coil latching | 12 V DC | 1 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 16.6 mA Reset coil: 16.6 mA | Set coil: 720 Ω Reset coil: 720 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,500 VA (AC), 300 W (DC) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC |
| | Single side stable | 12 V DC | 1 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | Max. 70% V of rated coil voltage (Initial) | | Min. 10% V of rated coil voltage (Initial) | | 16.6 mA | 720 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,500 VA (AC), 300 W (DC) | AgSnO2 type | 10 A 250 V AC, 10 A 30 V DC | 250 V AC, 30 V DC | 10 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | | | Max. 10 ms at rated coil voltage (without bounce) | | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC |
| | 2 coil latching | 24 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 8.3 mA Reset coil: 8.3 mA | Set coil: 2,880 Ω Reset coil: 2,880 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | 4,000 Vrms for 1 min (detection current: 10 mA) | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC |
| | Single side stable | 24 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | Max. 70% V of rated coil voltage (Initial) | | Min. 10% V of rated coil voltage (Initial) | | 8.3 mA | 2,880 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | | | Max. 10 ms at rated coil voltage (without bounce) | 4,000 Vrms for 1 min (detection current: 10 mA) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC |
| | 2 coil latching | 5 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 40 mA Reset coil: 40 mA | Set coil: 125 Ω Reset coil: 125 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | 4,000 Vrms for 1 min (detection current: 10 mA) | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC |
| | 2 coil latching | 5 V DC | 2 Form A | Sealed | PC board terminal | [Between contact and coil] Min. 8 mm (Clearance and Creepage) | Tube package | 20 | 500 | | Max. 70% V of rated coil voltage (Initial) | | Max. 70% V of rated coil voltage (Initial) | Set coil: 40 mA Reset coil: 40 mA | Set coil: 125 Ω Reset coil: 125 Ω | 200 mW | 130% V of rated coil voltage | Single | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | 2,000 VA (AC), 240 W (DC) | AgSnO2 type | 8 A 250 V AC, 8 A 30 V DC | 250 V AC, 30 V DC | 8 A | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | | 4,000 Vrms for 1 min (detection current: 10 mA) | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3 mm) | Min. 10x106 ope. (switching frequency: at 300 times/min) | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 7 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |