DE Relays

Panasonic’s DE Series Polarized Power Relays are distinguished by their compact body, providing board space, and low nominal operating power at 200 mW, single side stable, 2 coil latching. These DE Series Relays are ideal for various applications, including OA and FA equipment, automatic meter readings, and temperature controllers.

Features:

  • Conforms to European Safety Standard (VDE0700 and VDE0631)  
  • Insulating Distance Between Coil and Contacts: Clearance Min. 8mm .315 inch, Creepage Min. 8mm .315 inch
  • Low Operating Power
  • Compact Body with Size of 12.5 (W) × 25 (L) × 12.5 (H) mm [ .492 (W) × .984 (L) × .492 (H) inch]
  • Conforms to the Various Safety Standards: UL, C-UL and VDE Approved

Part Number List

Results 18
Models table for series DE Relays
Part No.DatasheetOperating Function Rated Coil VoltageContact ArrangementProtective ConstructionTerminal TypeInsulation DistancePacking QuantityPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Set Voltage Release Voltage (at20°C) Reset VoltageRated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ShapeContact Resistance (Initial)Max. Switching Power (Resistive Load) Contact MaterialContact Rating (Resistive Load)Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F) Operate Time (Initial) (At 20oC)Dielectric Strength (Initial): Between Contact SetsRelease Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
2 coil latching
5 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 40 mA
Reset coil: 40 mA
Set coil: 125 Ω
Reset coil: 125 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
4,000 Vrms for 1 min. (detection current: 10 mA)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 8 A 30 V DC (at 20 times/min.)
Single side stable
24 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
8.3 mA
2,880 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
4,000 Vrms for 1 min. (detection current: 10 mA)
Max. 5 ms (at rated coil voltage, without bounce, without diode)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 8 A 30 V DC (at 20 times/min.)
2 coil latching
12 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
4,000 Vrms for 1 min. (detection current: 10 mA)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 8 A 30 V DC (at 20 times/min.)
2 coil latching
5 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 40 mA
Reset coil: 40 mA
Set coil: 125 Ω
Reset coil: 125 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
4,000 Vrms for 1 min. (detection current: 10 mA)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 50,000 ope. 8 A 30 V DC (at 20 times/min.)
2 coil latching
24 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 8.3 mA
Reset coil: 8.3 mA
Set coil: 2,880 Ω
Reset coil: 2,880 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
4,000 Vrms for 1 min. (detection current: 10 mA)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 8 A 30 V DC (at 20 times/min.)
Single side stable
5 V DC
1 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
40 mA
125 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,500 VA (AC), 300 W (DC)
AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
250 V AC, 30 V DC
10 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 5 ms (at rated coil voltage, without bounce, without diode)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.)
Single side stable
24 V DC
1 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
8.3 mA
2,880 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,500 VA (AC), 300 W (DC)
AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
250 V AC, 30 V DC
10 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 5 ms (at rated coil voltage, without bounce, without diode)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.)
2 coil latching
12 V DC
1 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,500 VA (AC), 300 W (DC)
AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
250 V AC, 30 V DC
10 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 10 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 10 A 30 V DC (at 20 times/min.)
Single side stable
12 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
16.6 mA
720 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
4,000 Vrms for 1 min. (detection current: 10 mA)
Max. 5 ms (at rated coil voltage, without bounce, without diode)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 100,000 ope. 8 A 30 V DC (at 20 times/min.)
2 coil latching
12 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of Rated coil voltage (initial)
Max. 70% V of Rated coil voltage (initial)
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
200 mW
130% V of Rated coil voltage (initial)
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
2,000 VA (AC), 240 W (DC)
AgSnO2 type
8 A 250 V AC, 8 A 30 V DC
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min. (detection current: 10 mA)
5,000 Vrms for 1 min. (detection current: 10 mA)
12,000 V
Max. 10 ms (at rated coil voltage, without bounce)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
4,000 Vrms for 1 min. (detection current: 10 mA)
Min. 196 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2.0 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3.0 mm)
Min. 1x107 ope. (at 300 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 7 g
Min. 100,000 ope. 8 A 250 V AC (at 20 times/min.)
Min. 50,000 ope. 8 A 30 V DC (at 20 times/min.)

What's New

Stay up to date