DE Series Relays

Panasonic’s DE Series Polarized Power Relays are distinguished by their compact body, providing board space, and low nominal operating power at 200 mW, single side stable, 2 coil latching. These DE Series Relays are ideal for various applications, including OA and FA equipment, automatic meter readings, and temperature controllers.

Features:

  • Conforms to European Safety Standard (VDE0700 and VDE0631)  
  • Insulating Distance Between Coil and Contacts: Clearance Min. 8mm .315 inch, Creepage Min. 8mm .315 inch
  • Low Operating Power
  • Compact Body with Size of 12.5 (W) × 25 (L) × 12.5 (H) mm [ .492 (W) × .984 (L) × .492 (H) inch]
  • Conforms to the Various Safety Standards: UL, C-UL and VDE Approved

Panasonic Parametric Search Tool

Parametric Search Tool)414x233

Quickly And Accurately Isolate The Right Part Based On Key Product Attributes

With intuitive, drop-down filtered search and selection, Panasonic’s Parametric Search Tool allows users to narrow their search criteria quickly and efficiently based on top ranked product attributes. Immediately access complete part number details, datasheets and available inventory with every search result! Simply choose the initial product, category and type to find products based on key specification criteria.

Part Number List

Results 18
Models table for series DE Series Relays
Part No.DatasheetOperating Function Rated Coil VoltageContact ArrangementProtective ConstructionTerminal TypeInsulation DistancePacking QuantityPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Set Voltage Release Voltage (at20°C) Reset VoltageRated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ShapeContact Resistance (Initial)Contact Rating (Resistive Load)Contact MaterialMax. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilTime (Initial) (at 20°C 68°F) (Initial) Dielectric Strength (Initial): Between Contact SetsOperate Time (Initial) (At 20oC)Reset Time (Initial) (at20°C 68°F) Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
2 coil latching
24 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 8.3 mA
Reset coil: 8.3 mA
Set coil: 2,880 Ω
Reset coil: 2,880 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC
Single side stable
12 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce)
Max. 5 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC
2 coil latching
12 V DC
1 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
AgSnO2 type
2,500 VA (AC), 300 W (DC)
250 V AC, 30 V DC
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Single side stable
12 V DC
1 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
AgSnO2 type
2,500 VA (AC), 300 W (DC)
250 V AC, 30 V DC
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 5 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Single side stable
24 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
8.3 mA
2,880 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce)
Max. 5 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC
2 coil latching
5 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 40 mA
Reset coil: 40 mA
Set coil: 125 Ω
Reset coil: 125 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
2 coil latching
24 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 8.3 mA
Reset coil: 8.3 mA
Set coil: 2,880 Ω
Reset coil: 2,880 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
Single side stable
24 V DC
1 Form A 1 Form B
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
8.3 mA
2,880 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce)
Max. 5 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
2 coil latching
12 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC
2 coil latching
5 V DC
2 Form A
Sealed
PC board terminal
[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Tube package
20
500
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Set coil: 40 mA
Reset coil: 40 mA
Set coil: 125 Ω
Reset coil: 125 Ω
200 mW
130% V of rated coil voltage
Single
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
AgSnO2 type
2,000 VA (AC), 240 W (DC)
250 V AC, 30 V DC
8 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 10 ms at rated coil voltage (without bounce)
4,000 Vrms for 1 min (detection current: 10 mA)
Max. 10 ms at rated coil voltage (without bounce, without diode)
196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 10x106 ope. (switching frequency: at 300 times/min)
Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7 g
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 50x103 ope. 8 A 30 V DC