Item | Performance characteristics |
---|---|
Operating Function | 1 coil latching |
Type Classification | Standard type (Without manual switch) |
Rated Coil Voltage | 12 V DC |
Protective Construction | Flux-resistant |
Terminal Type | PC board terminal |
Packing Quantity; Inner Carton (Pcs.) | 50 |
Packing Quantity; Outer Carton (Pcs.) | 200 |
Set Voltage | 75%V or less of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | Set coil: 83.3 mA Reset coil: 83.3 mA |
Reset Voltage | 75%V or less of rated coil voltage (Initial) |
Resistance [±10%] (at 20°C) | Set coil: 144 Ω Reset coil: 144 Ω |
Rated Operating Power | 1,000mW |
Max. Allowable Voltage (at 20°C 68°F) | 130% of rated voltage |
Contact Arrangement | 1 Form A |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 20mΩ (by voltage drop 24V DC 1A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 50 A 277 V AC |
Max. Switching Power (Resistive Load) | 13,850 VA (50A 277V AC) |
Max. Switching Voltage | 480 V AC |
Max. Switching Current | 50A (AC) |
Min. Switching Load (Reference Value) | 100mA 5V DC |
Insulation Resistance (Initial) | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength |
Dielectric Strength (Initial): Between Open Contacts | AC 1,500 Vrms for 1 min. (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | AC 4,000 Vrms for 1 min. (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 12,000 V |
Time (Initial) (at 20°C 68°F) (Initial) | Max. 20 ms (at rated coil voltage, without bounce) |
Reset Time (Initial) (at20°C 68°F) | Max. 20 ms (at rated coil voltage, without bounce) |
Vibration Resistance (Functional) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Hock Resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz at double amplitude of 2.0 mm |
Mechanical Life | Min. 1x106 (at 180 times/min.) |
Conditions | Ambient temperature: -40 to +85°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) |
Weight (Typ.) | Approx. 31 g |
Resistive Load | Min. 1x104 ope. 50A 277V AC (ON:OFF = 1s:9s) Min. 1x104 ope. 25A 277V AC (ON:OFF = 1s:9s) |
Inrush Load; Tungsten | Min. 2.5x104 ope. 2,400W 120V AC (ON:OFF = 1s:59s) |
Inrush Load; Electronic Ballast | Min. 6x103 ope. 20A 277V AC (ON:OFF = 1s:9s) |
Inrush Load; Capacitive (IEC 60669-1) | Min. 3x104 ope. 20A 250V AC 200 µF (ON:OFF = 1s:9s) |
Distributor | Quantity | Inventory Date |
---|---|---|
Newark, An Avnet Company United States Tel. 1-800-4-NEWARK | 5 | 01/17/2021 |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.
Panasonic Industrial Solutions for 5G Networking Applications