| | 1 coil latching | Standard type (Without manual switch) | 24 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 41.7 mA Reset coil: 41.7 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 576 Ω Reset coil: 576 Ω | 1,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 1 coil latching | Standard type (Without manual switch) | 5 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 200 mA Reset coil: 200 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 25 Ω Reset coil: 25 Ω | 1,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 2 coil latching | Manual switch type | 5 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 400 mA Reset coil: 400 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 12.5 Ω Reset coil: 12.5 Ω | 2,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 1 coil latching | Manual switch type | 5 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 200 mA Reset coil: 200 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 25 Ω Reset coil: 25 Ω | 1,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 2 coil latching | Standard type (Without manual switch) | 24 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 83.3 mA Reset coil: 83.3 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 288 Ω Reset coil: 288 Ω | 2,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 2 coil latching | Manual switch type | 24 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 83.3 mA Reset coil: 83.3 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 288 Ω Reset coil: 288 Ω | 2,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 2 coil latching | Manual switch type | 12 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 166.7 mA Reset coil: 166.7 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 72 Ω Reset coil: 72 Ω | 2,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 1 coil latching | Manual switch type | 12 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 83.3 mA Reset coil: 83.3 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 144 Ω Reset coil: 144 Ω | 1,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 2 coil latching | Standard type (Without manual switch) | 12 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 166.7 mA Reset coil: 166.7 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 72 Ω Reset coil: 72 Ω | 2,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |
| | 1 coil latching | Manual switch type | 24 V DC | Flux-resistant | PC board terminal | 50 | 200 | Max. 75% V of rated coil voltage (Initial) | Set coil: 41.7 mA Reset coil: 41.7 mA | Max. 75% V of rated coil voltage (Initial) | Set coil: 576 Ω Reset coil: 576 Ω | 1,000 mW | 130% V of rated coil voltage | 1 Form A | Single | Max. 20 mΩ (by voltage drop 24 V DC 1 A) | AgSnO2 type | 50 A 277 V AC | 13,850 VA (50 A 277 V AC) | 480 V AC | 50 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,500 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 12,000 V | Max. 20 ms at rated coil voltage (without bounce) | Max. 20 ms at rated coil voltage (without bounce) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 31 g | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 µF |