Specifications
Item | Performance characteristics |
---|---|
Operating Function | 2 coil latching |
Type Classification | Manual switch type |
Rated Coil Voltage | 24 V DC |
Protective Construction | Flux-resistant |
Terminal Type | PC board terminal |
Packing Quantity; Inner Carton (Pcs.) | 50 |
Packing Quantity; Outer Carton (Pcs.) | 200 |
Set Voltage | Max. 75% V of rated coil voltage (Initial) |
Reset Voltage | Max. 75% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | Set coil: 83.3 mA Reset coil: 83.3 mA |
Resistance [±10%] (at 20°C) | Set coil: 288 Ω Reset coil: 288 Ω |
Rated Operating Power | 2,000 mW |
Max. Allowable Voltage (at 20°C 68°F) | 130% V of rated coil voltage |
Contact Arrangement | 1 Form A |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 20 mΩ (by voltage drop 24 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 50 A 277 V AC |
Max. Switching Power (Resistive Load) | 13,850 VA (50 A 277 V AC) |
Max. Switching Voltage | 480 V AC |
Max. Switching Current | 50 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,500 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 12,000 V |
Time (Initial) (at 20°C 68°F) (Initial) | Max. 20 ms at rated coil voltage (without bounce) |
Reset Time (Initial) (at20°C 68°F) | Max. 20 ms at rated coil voltage (without bounce) |
Hock Resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical Life | Min. 106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +85℃ (Allowable temperature is from -40 to +70℃ at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Weight (Typ.) | Approx. 31 g |
Resistive Load | [switching frequency ON : OFF = 1 s : 9 s] Min. 100x103 ope. 25 A 277 V AC Min. 10x103 ope. 50 A 277 V AC |
Inrush Load; Tungsten | [switching frequency ON : OFF = 1 s : 59 s] Min. 25x103 ope. 2,400 W 120 V AC |
Inrush Load; Electronic Ballast | [switching frequency ON : OFF = 1 s : 9 s] Min. 6x103 ope. 20 A 277 V AC |
Inrush Load; Capacitive (IEC 60669-1) | [switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 20 A 250 V AC 200 μF |
Stock check
ADJH23124
What's New
Stay up to date
Latest Videos