| | Single side stable | 3 V DC | 1 Form A | Sealed | PC board terminal | Sockets are available. | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 100 mA | 30Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 8 A 250 V AC, 5 A 30 V DC | 2,000VA, 150W | 250 V AC, 125 V DC (0.2 A) | 8 A (AC), 5 A (DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | | | | | 50 | 500 | Single |
| | Single side stable | 12 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | Sockets are available. | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 25 mA | 480Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | | | | | 50 | 500 | Single |
| | Single side stable | 12 V DC | 2 Form A | Sealed | PC board terminal | Sockets are available. | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 25 mA | 480Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | | | | | 50 | 500 | Single |
| | Single side stable | 3 V DC | 2 Form A | Sealed | PC board terminal | Sockets are available. | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 100 mA | 30Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | | | | | 50 | 500 | Single |
| | Single side stable | 5 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | Sockets are available. | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 60 mA | 83Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | Max. 10 ms at rated coil voltage (without bounce) | Max. 5 ms at rated coil voltage (without bounce, without diode) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | | | | | 50 | 500 | Single |
| | 1 coil latching | 12 V DC | 1 Form A | Sealed | PC board terminal | Sockets are available. | | | 12.5 mA | 960Ω | 150 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 8 A 250 V AC, 5 A 30 V DC | 2,000VA, 150W | 250 V AC, 125 V DC (0.2 A) | 8 A (AC), 5 A (DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 50 | 500 | Single |
| | 1 coil latching | 9 V DC | 1 Form A | Sealed | PC board terminal | Sockets are available. | | | 16.7 mA | 540Ω | 150 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 8 A 250 V AC, 5 A 30 V DC | 2,000VA, 150W | 250 V AC, 125 V DC (0.2 A) | 8 A (AC), 5 A (DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 50 | 500 | Single |
| | 1 coil latching | 3 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | Sockets are available. | | | 50 mA | 60Ω | 150 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 50 | 500 | Single |
| | 2 coil latching | 24 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | Sockets are available. | | | 12.5 mA | 1,920Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 50 | 500 | Single |
| | 2 coil latching | 3 V DC | 1 Form A 1 Form B | Sealed | PC board terminal | Sockets are available. | | | 100 mA | 30Ω | 300 mW | 130% V of rated coil voltage | Max. 30 mΩ (by voltage drop 6 V DC 1 A) | Au-flashed AgSnO2 type | 5 A 250 V AC, 5 A 30 V DC | 1,250VA, 150W | 250 V AC, 125 V DC (0.2 A) | 5 A (AC, DC) | 10 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 3,000 Vrms for 1 min (detection current: 10 mA) | 5,000 V | | | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 2,000 Vrms for 1 min (detection current: 10 mA) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 3.5 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 4.5 g | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC | Max. 80% V of rated coil voltage (Initial) | Max. 80% V of rated coil voltage (Initial) | Max. 10 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 50 | 500 | Single |