Specifications
Item | Performance characteristics |
---|---|
Terminal Type | PC board terminal |
Rated Coil Voltage | 9 V DC |
Contact Arrangement | 1 Form A |
Protective Construction | Flux-resistant |
Operating Function | Single side stable |
Coil Insulation Class | Class E insulation |
Insulation Distance | [Between contact and coil] Clearance: Min. 8 mm, Creepage: Min. 9.5 mm |
Packing Quantity; Inner Carton (Pcs.) | 50 |
Packing Quantity; Outer Carton (Pcs.) | 200 |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 100 mA |
Resistance [±10%] (at 20°C) | 90 Ω |
Rated Operating Power | 900 mW |
Max. Allowable Voltage | 110% V of rated coil voltage (at 60℃) |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 20 A 250 V AC |
Max. Switching Power (Resistive Load) | 6,250 VA |
Max. Switching Voltage | 250 V AC |
Max. Switching Current | 25 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 20 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 15 ms at rated coil voltage (without bounce, with diode) |
Hock Resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical Life | Min. 2x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +60℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
Weight (Typ.) | Approx. 23 g |
Resistive Load | [at 20℃, switching frequency: 20 times/min] Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0) Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0) |
Inrush load; Compressor | [at 20℃, switching frequency: 20 times/min] Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC |
Inrush Load; Inverter | [at 20℃, switching frequency: 10 times/min] Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC |
Stock check
ALF1P09
What's New
Stay up to date
Latest Videos