Part Number List

Results 12
Models table for series LF Series Relays
Part No.DatasheetTerminal TypeRated Coil VoltageContact ArrangementProtective ConstructionOperating Function Coil Insulation ClassInsulation DistancePacking Quantity; Inner Carton (Pcs.) Operate Voltage (@20oC)Packing Quantity; Outer Carton (Pcs.)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Hock Resistance (Functional)Release Time (Initial) (at 20°C) Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive LoadInrush load; CompressorInrush Load; Inverter
PC board terminal
5 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
180 mA
27.8 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
PC board terminal
9 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
100 mA
90 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
12 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
75 mA
160 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
5 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
180 mA
27.8 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
9 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
100 mA
90 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
24 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
37.5 mA
640 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
PC board terminal
12 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
75 mA
160 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
18 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
50 mA
360 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
Tab terminal (TMP type)
6 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
150 mA
40 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC
PC board terminal
24 V DC
1 Form A
Flux-resistant
Single side stable
Class E insulation
[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
50
Max. 70% V of rated coil voltage (Initial)
200
Min. 10% V of rated coil voltage (Initial)
37.5 mA
640 Ω
900 mW
110% V of rated coil voltage (at 60°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
20 A 250 V AC
6,250 VA
250 V AC
25 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
10,000 V
Max. 20 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 15 ms at rated coil voltage (without bounce, with diode)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 2x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 23 g
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
[at 20°C, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
[at 20°C, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC