Specifications

Specifications table for model ALF1T24
ItemPerformance characteristics
Terminal TypeTab terminal (TMP type)
Rated Coil Voltage24 V DC
Contact Arrangement1 Form A
Protective ConstructionFlux-resistant
Operating Function Single side stable
Coil Insulation ClassClass E insulation
Insulation Distance[Between contact and coil]
Clearance: Min. 8 mm, Creepage: Min. 9.5 mm
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)200
Operate Voltage (@20oC)Max. 70% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)37.5 mA
Resistance [±10%] (at 20°C) 640 Ω
Rated Operating Power 900 mW
Max. Allowable Voltage 110% V of rated coil voltage (at 60℃)
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)20 A 250 V AC
Max. Switching Power (Resistive Load) 6,250 VA
Max. Switching Voltage250 V AC
Max. Switching Current25 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil5,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Operate Time (Initial) (At 20oC)Max. 20 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 15 ms at rated coil voltage (without bounce, with diode)
Hock Resistance (Functional)100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 1.5 mm)
Mechanical LifeMin. 2x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 23 g
Resistive Load[at 20℃, switching frequency: 20 times/min]
Min. 100x103 ope. 20 A 250 V AC (cosΦ = 1.0)
Min. 10x103 ope. 25 A 250 V AC (cosΦ = 1.0)
Inrush load; Compressor[at 20℃, switching frequency: 20 times/min]
Min. 100x103 ope. Inrush 70 A (cosΦ = 0.7), Steady 20 A (cosΦ = 0.9) 250 V AC
Inrush Load; Inverter [at 20℃, switching frequency: 10 times/min]
Min. 30x103 ope. Inrush 200 A, Steady 20 A 100 V AC
Min. 30x103 ope. Inrush 100 A, Steady 10 A 200 V AC

Stock check

Model image for ALF1T24

ALF1T24

Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays