| | 5 V DC | 1 Form A | Flux-resistant | Single side stable | PC board terminal | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 106.4 mA | 47 Ω | 530 mW | 130% V of Rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 277 V AC, 5 A 30 V DC | 2,770 VA, 150 W | 277 V AC, 30 V DC | 10 A (AC), 5 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 15 ms (at rated coil voltage, without bounce) | Max. 5 ms (at rated coil voltage, without bounce, without diode) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 12 g | Min. 100,000 ope. 10 A 277 V AC (at 20°C, ON : OFF = 1.5 s : 1.5 s) Min. 100,000 ope. 5 A 30 V DC (at 20°C, ON : OFF = 1.5 s : 1.5 s) |
| | 9 V DC | 1 Form A | Flux-resistant | Single side stable | PC board terminal | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 58.8 mA | 153 Ω | 530 mW | 130% V of Rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 277 V AC, 5 A 30 V DC | 2,770 VA, 150 W | 277 V AC, 30 V DC | 10 A (AC), 5 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 15 ms (at rated coil voltage, without bounce) | Max. 5 ms (at rated coil voltage, without bounce, without diode) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 12 g | Min. 100,000 ope. 10 A 277 V AC (at 20°C, ON : OFF = 1.5 s : 1.5 s) Min. 100,000 ope. 5 A 30 V DC (at 20°C, ON : OFF = 1.5 s : 1.5 s) |
| | 12 V DC | 1 Form A | Flux-resistant | Single side stable | PC board terminal | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 44.1 mA | 272 Ω | 530 mW | 130% V of Rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 277 V AC, 5 A 30 V DC | 2,770 VA, 150 W | 277 V AC, 30 V DC | 10 A (AC), 5 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 15 ms (at rated coil voltage, without bounce) | Max. 5 ms (at rated coil voltage, without bounce, without diode) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 12 g | Min. 100,000 ope. 10 A 277 V AC (at 20°C, ON : OFF = 1.5 s : 1.5 s) Min. 100,000 ope. 5 A 30 V DC (at 20°C, ON : OFF = 1.5 s : 1.5 s) |
| | 24 V DC | 1 Form A | Flux-resistant | Single side stable | PC board terminal | 100 | 500 | Max. 70% V of Rated coil voltage (initial) | Min. 10% V of Rated coil voltage (initial) | 22.1 mA | 1,087 Ω | 530 mW | 130% V of Rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 10 A 277 V AC, 5 A 30 V DC | 2,770 VA, 150 W | 277 V AC, 30 V DC | 10 A (AC), 5 A (DC) | 100 mA 5 V DC | Min. 1,000 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min. (detection current: 10 mA) | 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 15 ms (at rated coil voltage, without bounce) | Max. 5 ms (at rated coil voltage, without bounce, without diode) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 2x106 ope. (at 180 times/min.) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) | Approx. 12 g | Min. 100,000 ope. 10 A 277 V AC (at 20°C, ON : OFF = 1.5 s : 1.5 s) Min. 100,000 ope. 5 A 30 V DC (at 20°C, ON : OFF = 1.5 s : 1.5 s) |