Specifications

Specifications table for model ALQ124
ItemPerformance characteristics
Coil Insulation ClassClass B insulation
Rated Coil Voltage24 V DC
Contact Arrangement1 Form C
Protective ConstructionSealed
Operating Function Single side stable
Terminal TypePC board terminal
Relay Shape Slim type
Packing Quantity; Inner Carton (Pcs.) 100
Packing Quantity; Outer Carton (Pcs.)500
Operate Voltage (@20oC)Max. 75% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 5% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)16.7 mA
Resistance [±10%] (at 20°C) 1,440 Ω
Rated Operating Power 400 mW
Max. Allowable Voltage 110% V of rated coil voltage (at 85℃)
150% V of rated coil voltage (at 20℃)
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgNi type
Contact Rating (Resistive Load)N.O.: 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC
N.C.: 3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC
Max. Switching Power (Resistive Load) N.O.: 1,250 VA, 150 W
N.C.: 500 VA, 30 W
Max. Switching Voltage250 V AC, 30 V DC
Max. Switching CurrentN.O.: 10 A (125 V AC), 5 A (30 V DC)
N.C.: 3 A (125 V AC), 1 A (30 V DC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts750 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil8,000 V
Operate Time (Initial) (At 20oC)Max. 20 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 20 ms at rated coil voltage (without bounce, with diode)
Hock Resistance (Functional)196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2 mm)
Mechanical LifeMin. 10x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +85℃ (-40 to +60℃ at our standard packing condition)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 7 g
Resistive Load[at 20℃, Switching frequency: ON:OFF=1.5 s:1.5 s with diode]
Form A contact: Min. 100x103 ope. 5 A 30 V DC
Form A contact: Min. 50x103 ope. 10 A 125 V AC
Form A contact: Min. 50x103 ope. 5 A 250 V AC
Form B contact: Min. 200x103 ope. 3 A 125 V AC
Form B contact: Min. 200x103 ope. 2 A 250 V AC
Form B contact: Min. 100x103 ope. 1 A 30 V DC
Packing QuantityCarton
Contact TypeStandard type

Stock check

Model image for ALQ124

ALQ124

Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays