Dust Cover
Plug-in terminal
Slim type
100 V DC
740 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
7.4 mA
13,500 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V AC, 220 V DC
5 A (AC, DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 5 A 250 V AC
Sealed
Plug-in terminal
Slim type
12 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
30 mA
400 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
6 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
60 mA
100 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC
Dust Cover
Plug-in terminal
Slim type
24 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
30 mA
800 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
4 A 250 V AC, 5 A 30 V DC
1,000 VA, 150 W
250 V AC, 220 V DC
4 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 4 A 250 V AC
Dust Cover
Plug-in terminal
Slim type
12 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
60 mA
200 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
4 A 250 V AC, 5 A 30 V DC
1,000 VA, 150 W
250 V AC, 220 V DC
4 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 4 A 250 V AC
Sealed
Plug-in terminal
Slim type
24 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
30 mA
800 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
2 A 250 V AC, 5 A 30 V DC
500 VA, 150 W
250 V AC, 220 V DC
2 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC
Sealed
Plug-in terminal
Slim type
3 V DC
360 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
120 mA
25 Ω
135% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC
Sealed
Plug-in terminal
Slim type
12 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
60 mA
200 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
2 A 250 V AC, 5 A 30 V DC
500 VA, 150 W
250 V AC, 220 V DC
2 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC
Sealed
Plug-in terminal
Slim type
48 V DC
720 mW
4 Form C
Single side stable
Sockets are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
15 mA
3,200 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
2 A 250 V AC, 5 A 30 V DC
500 VA, 150 W
250 V AC, 220 V DC
2 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 19 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC
Sealed
Plug-in terminal
Slim type
100 V DC
740 mW
2 Form C
Single side stable
Socket and terminal are available.
20
200
Max. 80% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
7.4 mA
13,500 Ω
110% V of rated coil voltage (at 50℃)
Twin
Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Au-clad AgNi type
3 A 250 V AC, 5 A 30 V DC
750 VA, 150 W
250 V AC, 220 V DC
3 A (AC), 5 A (DC)
100 μA 1 V DC
Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
1,000 Vrms for 1 min (detection current: 10 mA)
2,000 Vrms for 1 min (detection current: 10 mA)
Max. 20 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 2 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +55℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 16 g
[switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC