| | Sealed | Plug-in terminal | Slim type | 12 V DC | 360 mW | 2 Form C | Single side stable | Socket and terminal are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 30 mA | 400 Ω | 135% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 3 A 250 V AC, 5 A 30 V DC | 750 VA, 150 W | 250 V AC, 220 V DC | 3 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 16 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 6 V DC | 360 mW | 2 Form C | Single side stable | Socket and terminal are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 60 mA | 100 Ω | 135% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 3 A 250 V AC, 5 A 30 V DC | 750 VA, 150 W | 250 V AC, 220 V DC | 3 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 16 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC |
| | Dust Cover | Plug-in terminal | Slim type | 100 V DC | 740 mW | 2 Form C | Single side stable | Socket and terminal are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 7.4 mA | 13,500 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 5 A 250 V AC, 5 A 30 V DC | 1,250 VA, 150 W | 250 V AC, 220 V DC | 5 A (AC, DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 16 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 5 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 100 V DC | 740 mW | 2 Form C | Single side stable | Socket and terminal are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 7.4 mA | 13,500 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 3 A 250 V AC, 5 A 30 V DC | 750 VA, 150 W | 250 V AC, 220 V DC | 3 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 16 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC |
| | Dust Cover | Plug-in terminal | Slim type | 24 V DC | 720 mW | 4 Form C | Single side stable | Sockets are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 30 mA | 800 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 4 A 250 V AC, 5 A 30 V DC | 1,000 VA, 150 W | 250 V AC, 220 V DC | 4 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 19 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 4 A 250 V AC |
| | Dust Cover | Plug-in terminal | Slim type | 12 V DC | 720 mW | 4 Form C | Single side stable | Sockets are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 60 mA | 200 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 4 A 250 V AC, 5 A 30 V DC | 1,000 VA, 150 W | 250 V AC, 220 V DC | 4 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 19 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 4 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 24 V DC | 720 mW | 4 Form C | Single side stable | Sockets are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 30 mA | 800 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 2 A 250 V AC, 5 A 30 V DC | 500 VA, 150 W | 250 V AC, 220 V DC | 2 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 19 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 3 V DC | 360 mW | 2 Form C | Single side stable | Socket and terminal are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 120 mA | 25 Ω | 135% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 3 A 250 V AC, 5 A 30 V DC | 750 VA, 150 W | 250 V AC, 220 V DC | 3 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 16 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 3 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 12 V DC | 720 mW | 4 Form C | Single side stable | Sockets are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 60 mA | 200 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 2 A 250 V AC, 5 A 30 V DC | 500 VA, 150 W | 250 V AC, 220 V DC | 2 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 19 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC |
| | Sealed | Plug-in terminal | Slim type | 48 V DC | 720 mW | 4 Form C | Single side stable | Sockets are available. | 20 | 200 | Max. 80% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 15 mA | 3,200 Ω | 110% V of rated coil voltage (at 50°C) | Twin | Max. 50 mΩ (by voltage drop 6 V DC 1 A) | Au-clad AgNi type | 2 A 250 V AC, 5 A 30 V DC | 500 VA, 150 W | 250 V AC, 220 V DC | 2 A (AC), 5 A (DC) | 100 µA 1 V DC | Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 1,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | Max. 20 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 2 mm) | Min. 50x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 19 g | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 2 A 250 V AC |