| | 6 V DC | 1 Form A | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 28.3 mA | 212 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 18 V DC | 1 Form A | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 9.4 mA | 1,906 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 24 V DC | 1 Form A | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 7.1 mA | 3,388 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 9 V DC | 1 Form A | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 18.9 mA | 476 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 5 V DC | 1 Form A | AgNi type/Au-plated | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 34.0 mA | 147 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 1 mA 1 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 6 V DC | 1 Form A | AgNi type/Au-plated | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 28.3 mA | 212 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 1 mA 1 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 48 V DC | 1 Form A | AgNi type/Au-plated | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 4.5 mA | 10,618 Ω | 217 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 1 mA 1 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |
| | 5 V DC | 1 Form C | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 34.0 mA | 147 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 49 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] N.O.: Min. 50x103 ope. 6 A 250 V AC N.C.: Min. 30x103 ope. 6 A 250 V AC |
| | 9 V DC | 1 Form C | AgNi type | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 18.9 mA | 476 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 49 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] N.O.: Min. 50x103 ope. 6 A 250 V AC N.C.: Min. 30x103 ope. 6 A 250 V AC |
| | 12 V DC | 1 Form A | AgNi type/Au-plated | Sealed | Single side stable | PC board terminal | Slim type | Tube package | 20 | 1,000 | Max. 70% V of rated coil voltage (Initial) | Min. 5% V of rated coil voltage (Initial) | 14.2 mA | 847 Ω | 170 mW | 120% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | 6 A 250 V AC | 1,500 VA | 250 V AC | 6 A (AC) | 1 mA 1 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 1,000 Vrms for 1 min (detection current: 10 mA) | 4,000 Vrms for 1 min (detection current: 10 mA) | 6,000 V | Max. 8 ms at rated coil voltage (without bounce) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 11 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 5x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 5 g | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC |