Specifications
Item | Performance characteristics |
---|---|
Operating Function | Single side stable |
Terminal Type | Plug-in terminal |
Rated Coil Voltage | 3 V DC |
Contact Arrangement | 2 Form C |
Protective Construction | Dust Cover |
Accessories | Terminal and mounting board are available. |
Packing Quantity; Inner Carton (Pcs.) | 20 |
Packing Quantity; Outer Carton (Pcs.) | 200 |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 100 mA |
Resistance [±10%] (at 20°C) | 30 Ω |
Rated Operating Power | 300 mW |
Max. Allowable Voltage (at 20°C 68°F) | 150% V of rated coil voltage |
Contact Shape | Twin |
Contact Resistance (Initial) | Max. 30 mΩ (by voltage drop 6 V DC 1 A) |
Contact Material | Stationary contact: Au flashed AgSnO2 type Movable contact: AgSnO2 type |
Contact Rating (Resistive Load) | 15 A 250 V AC, 10 A 30 V DC |
Max. Switching Power (Resistive Load) | 3,750 VA, 300 W |
Max. Switching Voltage | 250 V AC, 30 V DC (48 V DC: Max. 2 A) |
Max. Switching Current | 15 A (AC), 10 A (DC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,500 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact Sets | 3,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 3,000 Vrms for 1 min (detection current: 10 mA) |
Operate Time (Initial) (At 20oC) | Max. 50 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 20 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -50 to +60℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
Weight (Typ.) | Approx. 50 g |
Resistive Load | [switching frequency: at 20 times/min] Min. 100x103 ope. 15 A 250 V AC Min. 100x103 ope. 10 A 30 V DC |